NSTTF Gen 3 Topic 1 CSP Liquid-Pathway to SunShot Pipe Preheating System Comparison Report

Technical Report ·
DOI:https://doi.org/10.2172/1761941· OSTI ID:1761941
 [1];  [2]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
  2. Bridgers and Paxton, Albuquerque, NM (United States)

The primary objective of this report is to determine a viable pipe preheating system for a chloride-salt blend that can preheat the pipe to 450°C and withstand a maximum exposure temperature of 750°C. Preheating involves heating the pipe to a specific desired temperature, called preheat temperature, of the pipe. The temperature is maintained by heated molten salt flowing through the piping system. This report reviews 5-types of pipe preheating systems, of which three pipe preheating systems- MI cable, heat tape, and ceramic fiber heaters, were found to be viable for the Gen 3 Liquid Pathway application. The report reviews the pipe preheating efficiency of conduction verses radiant heat transfer. For each of the 5 types of pipe preheating systems, the report describes the system and addresses installation requirements, temperature control, reliability survey, and pre-construction verification testing for the most applicable preheating system. Under Appendix A, images from design drawings demonstrate pipe routing with the preheating system and insulation attached to the pipe along with pipe guides and pipe supports, as designed using Caesar II finite element analysis within the SNL NSTTF Solar Power Tower.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Bridgers and Paxton, Albuquerque, NM (United States)
Sponsoring Organization:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Renewable Power Office. Solar Energy Technologies Office; USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000; NA0003525
OSTI ID:
1761941
Report Number(s):
SAND--2019-3188R; 673656
Country of Publication:
United States
Language:
English

Similar Records

NSTTF Gen 3 Topic 1 CSP Liquid-Pathway to SunShot. Heat Trace Options Report
Technical Report · Thu Apr 11 00:00:00 EDT 2019 · OSTI ID:1762091

In-service operation of the heat pipe air preheater
Conference · Mon Dec 31 23:00:00 EST 1979 · Proc. Am. Power Conf.; (United States) · OSTI ID:5279647

Gen 3 Particle Pilot Plant (G3P3) Life Cycle Management Plan (SAND report)
Technical Report · Thu Sep 01 00:00:00 EDT 2022 · OSTI ID:1886755