Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Neutron and Gamma Radiation Monitoring at The Ion Beam Laboratory Building 720 Sandia/NM

Technical Report ·
DOI:https://doi.org/10.2172/1761345· OSTI ID:1761345
 [1];  [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

Neutron and gamma radiation spectra and dose rates were measured in and around the Ion Beam Laboratory, Building 720, at Sandia/NM. Measurements were made to support the testing of an enhanced target yielding 14 MeV neutrons from the deuterium-tritium (D-T) fusion reaction. The target room has thick concrete walls but an unshielded ceiling. Neutron and gamma radiation in and around the facility appear to be the result of skyshine. Estimates of neutron/gamma dose rates (per 10 9 source neutrons/s) at six (6) monitoring locations were made. Results indicated the need for enhanced radiological controls due to increased neutron production rates.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000; NA0003525
OSTI ID:
1761345
Report Number(s):
SAND--2018-12509; 670925
Country of Publication:
United States
Language:
English

Similar Records

14 MeV DT Neutron Test Facility at the Sandia Ion Beam Laboratory
Technical Report · Wed Jan 29 23:00:00 EST 2020 · OSTI ID:1596231

TFTR off-site dose levels from fusion radiation and effluent releases
Conference · Tue Dec 31 23:00:00 EST 1985 · Trans. Am. Nucl. Soc.; (United States) · OSTI ID:5503138

14 MeV DT Neutron Test Facility at the Sandia Ion Beam Laboratory
Technical Report · Sun Sep 01 00:00:00 EDT 2019 · OSTI ID:1569148