Mechanical Integrity Issues at MCM-Cs for High Reliability Applications
Conference
·
OSTI ID:16576
During the qualification of a new high reliability low-temperature cofired ceramic (LTCC) multichip module (MCM), two issues relating to the electrical and mechanical integrity of the LTCC network were encountered while performing qualification testing. One was electrical opens after aging tests that were caused by cracks in the solder joints. The other was fracturing of the LTCC networks during mechanical testing. Through failure analysis, computer modeling, bend testing, and test samples, changes were identified. Upon implementation of all these changes, the modules passed testing, and the MCM was placed into production.
- Research Organization:
- Kansas City Plant, Kansas City, MO (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number: