Analysis of Residual Explosives by Swab Touch Spray Ionization Mass Spectrometry
Journal Article
·
· Propellants, Explosives, Pyrotechnics
- Purdue Univ., West Lafayette, IN (United States); DOE/OSTI
- Purdue Univ., West Lafayette, IN (United States)
- Naval Surface Warfare Center Crane Division, Crane, IN (United States)
Swab touch spray ionization mass spectrometry, an ambient ionization technique, has been applied to the analysis of six explosives from various surfaces including glass, metal, Teflon, plastic, human hands and three types of gloves (nitrile, vinyl and latex). A swab, attached to a metallic handle, was used to sample explosive residues and acted as the ion source. The explosives, 1,3,5-trinitro-1,3,5-triazinane (RDX), 1,3,5,7-tetranitro-1,3,5,7-tetrazocane (HMX), and 2,2-bis[(nitrooxy)methyl]propane-1,3-diyl dinitrate (PETN) had an absolute limit of detection of 10 ng from all the surfaces except for PETN from the nitrile gloves (limit of detection 100 ng). Sodium perchlorate, 2-methyl-1,3,5-trinitrobenzene (TNT) and tetra-butylammonium perchlorate had limits of detection of 100 pg, 10 pg, and 1 pg, respectively from all surfaces. This study demonstrates the feasibility of swab touch spray ionization mass spectrometry for detection of a wide array of explosives from a variety of forensically applicable surfaces with disposable, commercial, tamperproof and individually-wrapped conductive swabs without complicated/lengthy sample preparations or extractions.
- Research Organization:
- Purdue University, West Lafayette, IN (United States)
- Sponsoring Organization:
- USDOE; USDOE Office of Science (SC), Basic Energy Sciences (BES)
- Grant/Contract Number:
- FG02-06ER15807
- OSTI ID:
- 1609707
- Alternate ID(s):
- OSTI ID: 1473990
- Journal Information:
- Propellants, Explosives, Pyrotechnics, Journal Name: Propellants, Explosives, Pyrotechnics Journal Issue: 11 Vol. 43; ISSN 0721-3115
- Publisher:
- WileyCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Utilizing Surface Acoustic Wave Nebulization (SAWN) for the Rapid and Sensitive Ambient Ionization Mass Spectrometric Analysis of Organic Explosives
|
journal | October 2019 |
Similar Records
Integration of paper spray ionization high‐field asymmetric waveform ion mobility spectrometry for forensic applications
Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment
Journal Article
·
Sun Mar 04 19:00:00 EST 2018
· Rapid Communications in Mass Spectrometry
·
OSTI ID:1425544
Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment
Journal Article
·
Sat May 15 00:00:00 EDT 2021
· Talanta
·
OSTI ID:1768862