Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Solid matrix transformation and tracer addition using molten ammonium bifluoride salt as a sample preparation method for laser ablation inductively coupled plasma mass spectrometry

Journal Article · · Analyst
DOI:https://doi.org/10.1039/c7an00777a· OSTI ID:1532263
 [1];  [2];  [1];  [1];  [1];  [1];  [1];  [1];  [3];  [2]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
  2. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Applied Spectra, Fremont, CA (United States)
  3. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

Solid sampling and analysis methods, such as laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), are challenged by matrix effects and calibration difficulties. Matrix-matched standards for external calibration are seldom available and it is difficult to distribute spikes evenly into a solid matrix as internal standards. While isotopic ratios of the same element can be measured to high precision, matrix-dependent effects in the sampling and analysis process frustrate accurate quantification and elemental ratio determinations. Here we introduce a potentially general solid matrix transformation approach entailing chemical reactions in molten ammonium bifluoride (ABF) salt that enables the introduction of spikes as tracers or internal standards. Proof of principle experiments show that the decomposition of uranium ore in sealed PFA fluoropolymer vials at 230 °C yields, after cooling, new solids suitable for direct solid sampling by LA. When spikes are included in the molten salt reaction, subsequent LA-ICP-MS sampling at several spots indicate that the spikes are evenly distributed, and that U-235 tracer dramatically improves reproducibility in U-238 analysis. Precisions improved from 17% relative standard deviation for U-238 signals to 0.1% for the ratio of sample U-238 to spiked U-235, a factor of over two orders of magnitude. These results introduce the concept of solid matrix transformation (SMT) using ABF, and provide proof of principle for a new method of incorporating internal standards into a solid for LA-ICP-MS. This new approach, SMT-LA-ICP-MS, provides opportunities to improve calibration and quantification in solids based analysis. Finally, looking forward, tracer addition to transformed solids opens up LA-based methods to analytical methodologies such as standard addition, isotope dilution, preparation of matrix-matched solid standards, external calibration, and monitoring instrument drift against external calibration standard

Research Organization:
Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
Grant/Contract Number:
AC02-05CH11231
OSTI ID:
1532263
Alternate ID(s):
OSTI ID: 1390422
Journal Information:
Analyst, Journal Name: Analyst Journal Issue: 18 Vol. 142; ISSN ANALAO; ISSN 0003-2654
Publisher:
Royal Society of ChemistryCopyright Statement
Country of Publication:
United States
Language:
English

References (41)

Femtosecond laser ablation inductively coupled plasma mass spectrometry: Fundamentals and capabilities for depth profiling analysis journal November 2008
An uncertainty budget for trace analysis by isotope-dilution ICP-MS with proper consideration of correlation journal September 2003
Application of isotope-dilution laser ablation ICP?MS for direct determination of Pu concentrations in soils at pg�g?1 levels journal January 2004
Development of an accurate, sensitive, and robust isotope dilution laser ablation ICP-MS method for simultaneous multi-element analysis (chlorine, sulfur, and heavy metals) in coal samples journal July 2007
Recent advances in quantitative LA-ICP-MS analysis: challenges and solutions in the life sciences and environmental chemistry journal July 2015
A new strategy of solution calibration in laser ablation inductively coupled plasma mass spectrometry for multielement trace analysis of geological samples journal September 2000
Use of a single calibration graph for the determination of major elements in geological materials by laser ablation inductively coupled plasma atomic emission spectrometry with added internal standards journal February 1999
Development of ammonium bifluoride fusion method for rapid dissolution of trinitite samples and analysis by ICP-MS journal August 2015
Analysis of U and Th in soils and sediments B—Why do we sometimes get the WRONG RESULT? journal October 2015
Laser ablation in analytical chemistry—a review journal May 2002
Laser ablation sampling journal August 1998
Determination of minor and trace elements in obsidian rock samples and archaeological artifacts by laser ablation inductively coupled plasma mass spectrometry using synthetic obsidian standards journal October 2001
Applications of inductively coupled plasma mass spectrometry and laser ablation inductively coupled plasma mass spectrometry in materials science journal December 2002
Elemental analyses of soil and sediment fused with lithium borate using isotope dilution laser ablation-inductively coupled plasma-mass spectrometry journal September 2013
Analysis of uranium in the insoluble residues after decomposition of soil samples by various techniques journal May 2014
Decomposition of diverse solid inorganic matrices with molten ammonium bifluoride salt for constituent elemental analysis journal September 2017
Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS journal April 2005
Biomonitoring of hair samples by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) journal March 2007
Calibration and correction of LA-ICP-MS and LA-MC-ICP-MS analyses for element contents and isotopic ratios journal June 2016
Total Rock Dissolution Using Ammonium Bifluoride (NH 4 HF 2 ) in Screw-Top Teflon Vials: A New Development in Open-Vessel Digestion journal November 2012
Standard Addition Method for Laser Ablation ICPMS Using a Spinning Platform journal March 2013
Laser Ablation in Analytical Chemistry journal May 2013
Fast Decomposition Procedure of Solid Samples by Lithium Borates Fusion Employing Salicylic Acid journal February 2017
Development of Solid Calibration Standards for Trace Elemental Analyses of Tree Rings by Laser Ablation Inductively Coupled Plasma-Mass Spectrometry journal July 1998
Isotope dilution mass spectrometry as a calibration method for the analysis of trace elements in powder samples by LA-ICP-MS journal January 2003
Study of particle size influence on laser ablation inductively coupled plasma mass spectrometry using an in-line cascade impactor journal January 2005
Non-matrix matched calibration of major and minor concentrations of Zn and Cu in brass, aluminium and silicate glass using NIR femtosecond laser ablation inductively coupled plasma mass spectrometry journal January 2006
UV-femtosecond and nanosecond laser ablation-ICP-MS: internal and external repeatability journal January 2006
Validation of LA-ICP-MS trace element analysis of geological glasses using a new solid-state 193 nm Nd:YAG laser and matrix-matched calibration journal January 2007
Assessment of the precision and accuracy of thorium ( 232 Th) and uranium ( 238 U) measured by quadrupole based inductively coupled plasma-mass spectrometry using liquid nebulization, nanosecond and femtosecond laser ablation journal January 2008
Solid-spiking isotope dilution laser ablation ICP-MS for the direct and simultaneous determination of trace elements in soils and sediments journal January 2008
Current approaches to calibration of LA-ICP-MS analysis journal January 2015
Study on aerosol characteristics and fractionation effects of organic standard materials for bioimaging by means of LA-ICP-MS journal January 2015
Particle size-related elemental fractionation in laser ablation in liquid inductively coupled plasma mass spectrometry journal January 2015
Non-matrix matched calibration using near-IR femtosecond laser ablation inductively coupled plasma optical emission spectrometry journal January 2005
Critical revision of GD-MS, LA-ICP-MS and SIMS as inorganic mass spectrometric techniques for direct solid analysis journal January 2009
Laser ablation—laser induced breakdown spectroscopy (LA-LIBS): A means for overcoming matrix effects leading to improved analyte response journal January 2009
Accuracy and precision of non-matrix-matched calibration for lead isotope ratio measurements of lead-poor minerals by LA-MC-ICPMS journal January 2010
Quantification strategies for elemental imaging of biological samples using laser ablation-inductively coupled plasma-mass spectrometry journal January 2012
The Development of Laser Ablation ICP-MS and Calibration Strategies: Examples from the Analysis of Trace Elements in Volcanic Glass Shards and Sulfide Minerals journal December 1997
Laser Ablation ICP-MS Analysis of Geological Materials Prepared as Lithium Borate Glasses journal July 2003

Cited By (3)

Recent advances in single-cell analysis by mass spectrometry journal January 2019
In situ analytical characterization and chemical imaging of tablet coatings using laser induced breakdown spectroscopy (LIBS) journal January 2018
Atomic Spectrometry Update – a review of advances in environmental analysis journal January 2019