Title: NSLS-II Storage Ring BPM Calibration via LOCO

Technical Report ·
DOI:https://doi.org/10.2172/1504718· OSTI ID:1504718
 [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States). Photon Sciences Directorate

In the following, we describe a method of the beam based calibration of the beam position monitor (BPM) system in the NSLS-II storage ring (SR) via the LOCO (Linear Optics from Closed Orbits) technique. This method measures the orbit response matrix (ORM) and the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Therefore, BPM gains and rolls are obtained.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Basic Energy Sciences (BES)
DOE Contract Number:
SC0012704
OSTI ID:
1504718
Report Number(s):
NSLSII-ASD-TN-248; BNL-211194-2019-TECH
Country of Publication:
United States
Language:
English

Similar Records

Applying Matlab LOCO to the NSLSII Storage Ring Commissioning
Technical Report · Mon Jun 02 00:00:00 EDT 2014 · OSTI ID:1504718

LOCO with Constraints and Improved Fitting Technique
Journal Article · Thu Jun 18 00:00:00 EDT 2009 · ICFA Beam Dyn.Newslett.44:60-69,2007 · OSTI ID:1504718

Calibration of the X-ray ring quadrupoles, BPMs, and orbit correctors using the measured orbit response matrix
Conference · Fri Aug 05 00:00:00 EDT 1994 · AIP Conference Proceedings (American Institute of Physics); (United States) · OSTI ID:1504718

Related Subjects