Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Calibration of the x-ray ring quadrupoles, BPMs, and orbit correctors using the measured orbit response matrix

Conference ·
OSTI ID:10136540
 [1];  [2]
  1. Brookhaven National Lab., Upton, NY (United States)
  2. Stanford Linear Accelerator Center, Menlo Park, CA (United States)
The quadrupole strengths, beam position monitor (BPM) gains, and orbit correction magnet strengths were adjusted in a computer model of the NSLS X-Ray ring in order to best fit the model orbit response matrix to the measured matrix. The model matrix was fit tot the 4320 data points in the measured matrix with an rms difference of only 2 to 3 microns, which is due primarily to noise in the BPM measurements. The strengths of the 56 individual quadrupoles in the X-Ray ring were determined to an accuracy of about 0.2%. The BPM and orbit corrector calibrations were also accurately determined. A through analysis of both random and systematic errors is included.
Research Organization:
Stanford Linear Accelerator Center, Menlo Park, CA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC03-76SF00515; AC02-76CH00016
OSTI ID:
10136540
Report Number(s):
SLAC-PUB--6442; BNL--61250; CONF-931254--7; ON: DE94009029
Country of Publication:
United States
Language:
English

Similar Records

Calibration of the X-ray ring quadrupoles, BPMs, and orbit correctors using the measured orbit response matrix
Conference · Fri Aug 05 00:00:00 EDT 1994 · AIP Conference Proceedings (American Institute of Physics); (United States) · OSTI ID:6978933

NSLS-II Storage Ring BPM Calibration via LOCO
Technical Report · Mon Apr 10 00:00:00 EDT 2017 · OSTI ID:1504718

Global DC closed orbit correction experiments on the NSLS X-ray ring and SPEAR
Conference · Thu Jul 01 00:00:00 EDT 1993 · OSTI ID:10176007