Title: Thermal Energy Delivery System Operational Characteristics and Control Strategies

Abstract

Nuclear Renewable Hybrid Energy Systems (NR-HES) is an area of current research interest as wind and solar grid penetrations continue to increase. The goal of these systems is to operate at ~100% capacity and store excess energy, when available, for later use. To store this excess energy some form of storage is needed. Sensible heat Thermal Energy Storage (TES) systems have been shown to be an effective thermal load management strategy allowing nuclear reactor systems to operate at effectively 100% full power while storing excess thermal energy for recovery at a later time. Thermal storage is modeled extensively around the world. However, little in the way of experimentation is being conducted. Experimentation is needed to verify the dynamics and control of TES systems. To complement the modeling and simulation efforts on nuclear-renewable hybrid energy systems, Idaho National Laboratory (INL) is designing a Thermal Energy Delivery System (TEDS). The system will provide a means of distributing thermal energy to and from various co-located systems located in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL). DETAIL will include a high-pressure high-temperature water flow loop simulating a Pressurized Water Reactor (PWR), a 25 kWe High-Temperature Steam Electrolysis (HTSE) unit (first potential heatmore » user/customer) and a packed-bed Thermal Energy Storage (TES) system. The thermal energy transfer from TEDS can be used in a flexible, dynamic manner incorporating charging and discharging cycles from the TES system, to support test/demonstration operations for nuclear-renewable hybrid energy systems (N-R HES) applications. This paper discusses the design, operation, instrumentation (sensors), and control strategies to enable the dynamic operation of TEDS.« less

Authors:
ORCiD logo [1];  [2]; ORCiD logo [1]; ORCiD logo [1]; ORCiD logo [1]; ORCiD logo [1]; ORCiD logo [1];  [3]
  1. Idaho National Laboratory
  2. Oregon State University
  3. Montana State University
Publication Date:
Research Org.:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1498251
Report Number(s):
INL/CON-18-51322-Rev000
DOE Contract Number:  
AC07-05ID14517
Resource Type:
Conference
Resource Relation:
Conference: 11th Nuclear Plant Instrumentation, Control and Human Machine Interface Technologies (NPIC & HMIT) 2019, Orlando Florida, 02/09/2019 - 02/14/2019
Country of Publication:
United States
Language:
English
Subject:
46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; TEDS; NR-HES; Thermal Energy Storage

Citation Formats

Frick, Konor L, Duenas, Alexander, Sabharwall, Piyush, Yoo, Jun Soo, Yoon, Su Jong, Stoots, Carl M, O'Brien, James E, and O'Brien, Thomas. Thermal Energy Delivery System Operational Characteristics and Control Strategies. United States: N. p., 2019. Web.
Frick, Konor L, Duenas, Alexander, Sabharwall, Piyush, Yoo, Jun Soo, Yoon, Su Jong, Stoots, Carl M, O'Brien, James E, & O'Brien, Thomas. Thermal Energy Delivery System Operational Characteristics and Control Strategies. United States.
Frick, Konor L, Duenas, Alexander, Sabharwall, Piyush, Yoo, Jun Soo, Yoon, Su Jong, Stoots, Carl M, O'Brien, James E, and O'Brien, Thomas. Wed . "Thermal Energy Delivery System Operational Characteristics and Control Strategies". United States. https://www.osti.gov/servlets/purl/1498251.
@article{osti_1498251,
title = {Thermal Energy Delivery System Operational Characteristics and Control Strategies},
author = {Frick, Konor L and Duenas, Alexander and Sabharwall, Piyush and Yoo, Jun Soo and Yoon, Su Jong and Stoots, Carl M and O'Brien, James E and O'Brien, Thomas},
abstractNote = {Nuclear Renewable Hybrid Energy Systems (NR-HES) is an area of current research interest as wind and solar grid penetrations continue to increase. The goal of these systems is to operate at ~100% capacity and store excess energy, when available, for later use. To store this excess energy some form of storage is needed. Sensible heat Thermal Energy Storage (TES) systems have been shown to be an effective thermal load management strategy allowing nuclear reactor systems to operate at effectively 100% full power while storing excess thermal energy for recovery at a later time. Thermal storage is modeled extensively around the world. However, little in the way of experimentation is being conducted. Experimentation is needed to verify the dynamics and control of TES systems. To complement the modeling and simulation efforts on nuclear-renewable hybrid energy systems, Idaho National Laboratory (INL) is designing a Thermal Energy Delivery System (TEDS). The system will provide a means of distributing thermal energy to and from various co-located systems located in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL). DETAIL will include a high-pressure high-temperature water flow loop simulating a Pressurized Water Reactor (PWR), a 25 kWe High-Temperature Steam Electrolysis (HTSE) unit (first potential heat user/customer) and a packed-bed Thermal Energy Storage (TES) system. The thermal energy transfer from TEDS can be used in a flexible, dynamic manner incorporating charging and discharging cycles from the TES system, to support test/demonstration operations for nuclear-renewable hybrid energy systems (N-R HES) applications. This paper discusses the design, operation, instrumentation (sensors), and control strategies to enable the dynamic operation of TEDS.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2019},
month = {1}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: