Title: Status on the Component Models Developed in the Modelica Framework: High-Temperature Steam Electrolysis Plant & Gas Turbine Power Plant

Abstract

This report has been prepared as part of an effort to design and build a modeling and simulation (M&S) framework to assess the economic viability of a nuclear-renewable hybrid energy system (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In fiscal year (FY) 2015, Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water reverse osmosis desalination plants as industrial processes. In FY 2016, INL has developed two additional subsystems in the Modelica framework: a high-temperature steam electrolysis (HTSE) plant and a gas turbine power plant (GTPP). HTSE has been proposed as a high priority industrial process to be integrated with a light water reactor (LWR) in an N-R HES. This integrated energy system would be capable of dynamically apportioning thermal and electrical energy (1) to provide responsive generation to the power grid and (2) to produce alternative industrial products (i.e., hydrogen and oxygen) without generating any greenhouse gases. A dynamic performance analysis of the LWR/HTSE integration case wasmore » carried out to evaluate the technical feasibility (load-following capability) and safety of such a system operating under highly variable conditions requiring flexible output. To support the dynamic analysis, the detailed dynamic model and control design of the HTSE process, which employs solid oxide electrolysis cells, have been developed to predict the process behavior over a large range of operating conditions. As first-generation N-R HES technology will be based on LWRs, which provide thermal energy at a relatively low temperature, complementary temperature-boosting technology was suggested for integration with the HTSE process that requires higher temperature input. Simulation results involving several case studies show that the suggested control scheme could maintain the controlled variables (including the steam utilization factor, cathode stream inlet composition, and temperatures of the process streams at various locations) within desired limits under various plant operating conditions. The results also indicate that the proposed HTSE plant could provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess plant capacity within an N-R HES. A natural-gas fired GTPP has been proposed as a secondary energy supply to be included in an N-R HES. This auxiliary generator could be used to cover rapid dynamics in grid demand that cannot be met by the remainder of the N-R HES. To evaluate the operability and controllability of the proposed process during transients between load (demand) levels, the dynamic model and control design were developed. Special attention was given to the design of feedback controllers to regulate the power frequency, and exhaust gas and turbine firing temperatures. Several case studies were performed to investigate the system responses to the major disturbance (power load demand) in such a control system. The simulation results show that the performance of the proposed control strategies was satisfactory under each test when the GTPP experienced high rapid variations in the load.« less

Authors:
 [1];  [1];  [1];  [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)
Publication Date:
Research Org.:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
Sponsoring Org.:
USDOE Office of Nuclear Energy (NE)
OSTI Identifier:
1333156
Report Number(s):
INL/EXT-16-40305
DOE Contract Number:
AC07-05ID14517
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
08 HYDROGEN; 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; 42 ENGINEERING; 97 MATHEMATICS AND COMPUTING; High-temperature steam electrolysis; Solid oxide electrolysis cell; Gas turbine power plant; Nuclear-renewable hybrid energy system

Citation Formats

Suk Kim, Jong, McKellar, Michael, Bragg-Sitton, Shannon M., and Boardman, Richard D.. Status on the Component Models Developed in the Modelica Framework: High-Temperature Steam Electrolysis Plant & Gas Turbine Power Plant. United States: N. p., 2016. Web. doi:10.2172/1333156.
Suk Kim, Jong, McKellar, Michael, Bragg-Sitton, Shannon M., & Boardman, Richard D.. Status on the Component Models Developed in the Modelica Framework: High-Temperature Steam Electrolysis Plant & Gas Turbine Power Plant. United States. doi:10.2172/1333156.
Suk Kim, Jong, McKellar, Michael, Bragg-Sitton, Shannon M., and Boardman, Richard D.. Sat . "Status on the Component Models Developed in the Modelica Framework: High-Temperature Steam Electrolysis Plant & Gas Turbine Power Plant". United States. doi:10.2172/1333156. https://www.osti.gov/servlets/purl/1333156.
@article{osti_1333156,
title = {Status on the Component Models Developed in the Modelica Framework: High-Temperature Steam Electrolysis Plant & Gas Turbine Power Plant},
author = {Suk Kim, Jong and McKellar, Michael and Bragg-Sitton, Shannon M. and Boardman, Richard D.},
abstractNote = {This report has been prepared as part of an effort to design and build a modeling and simulation (M&S) framework to assess the economic viability of a nuclear-renewable hybrid energy system (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In fiscal year (FY) 2015, Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water reverse osmosis desalination plants as industrial processes. In FY 2016, INL has developed two additional subsystems in the Modelica framework: a high-temperature steam electrolysis (HTSE) plant and a gas turbine power plant (GTPP). HTSE has been proposed as a high priority industrial process to be integrated with a light water reactor (LWR) in an N-R HES. This integrated energy system would be capable of dynamically apportioning thermal and electrical energy (1) to provide responsive generation to the power grid and (2) to produce alternative industrial products (i.e., hydrogen and oxygen) without generating any greenhouse gases. A dynamic performance analysis of the LWR/HTSE integration case was carried out to evaluate the technical feasibility (load-following capability) and safety of such a system operating under highly variable conditions requiring flexible output. To support the dynamic analysis, the detailed dynamic model and control design of the HTSE process, which employs solid oxide electrolysis cells, have been developed to predict the process behavior over a large range of operating conditions. As first-generation N-R HES technology will be based on LWRs, which provide thermal energy at a relatively low temperature, complementary temperature-boosting technology was suggested for integration with the HTSE process that requires higher temperature input. Simulation results involving several case studies show that the suggested control scheme could maintain the controlled variables (including the steam utilization factor, cathode stream inlet composition, and temperatures of the process streams at various locations) within desired limits under various plant operating conditions. The results also indicate that the proposed HTSE plant could provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess plant capacity within an N-R HES. A natural-gas fired GTPP has been proposed as a secondary energy supply to be included in an N-R HES. This auxiliary generator could be used to cover rapid dynamics in grid demand that cannot be met by the remainder of the N-R HES. To evaluate the operability and controllability of the proposed process during transients between load (demand) levels, the dynamic model and control design were developed. Special attention was given to the design of feedback controllers to regulate the power frequency, and exhaust gas and turbine firing temperatures. Several case studies were performed to investigate the system responses to the major disturbance (power load demand) in such a control system. The simulation results show that the performance of the proposed control strategies was satisfactory under each test when the GTPP experienced high rapid variations in the load.},
doi = {10.2172/1333156},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Sat Oct 01 00:00:00 EDT 2016},
month = {Sat Oct 01 00:00:00 EDT 2016}
}

Technical Report:

Save / Share:
  • This report has been prepared as part of an effort to design and build a modeling and simulation (M&S) framework to assess the economic viability of a nuclear-renewable hybrid energy system (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In fiscal year 2015 (FY15), Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water reverse osmosis desalination plants asmore » industrial processes. In FY16, INL developed two additional subsystems in the Modelica framework: (1) a high-temperature steam electrolysis (HTSE) plant as a high priority industrial plant to be integrated with a light water reactor (LWR) within an N-R HES and (2) a gas turbine power plant as a secondary energy supply. In FY17, five new components (i.e., a feedwater pump, a multi-stage compression system, a sweep-gas turbine, flow control valves, and pressure control valves) have been incorporated into the HTSE system proposed in FY16, aiming to better realistically characterize all key components of concern. Special attention has been given to the controller settings based on process models (i.e., direct synthesis method), aiming to improve process dynamics and controllability. A dynamic performance analysis of the improved LWR/HTSE integration case was carried out to evaluate the technical feasibility (load-following capability) and safety of such a system operating under highly variable conditions requiring flexible output. The analysis (evaluated in terms of the step response) clearly shows that the FY17 model resulted in superior output responses with much smaller settling times and less oscillatory behavior in response to disturbances in the electric load than those observed with the FY16 model. Simulation results involving several case studies show that the suggested control scheme could maintain the controlled variables (including the steam utilization factor, cathode stream inlet composition, and temperatures and pressures of the process streams at various locations) within desired limits under various plant operating conditions. The results also indicate that the proposed HTSE plant could provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess plant capacity within an N-R HES.« less
  • An overview is provided of the design, operation, performance, and maintenance of a 750 MW (net) combined cycle plant with integrated coal gasification producing low Btu gas consisting of 520 MW generated by two double-ended generators each driven by two gas turbines, and 230 MW generated by a condensing steam turbine generator. Overall plant efficiency with the gas turbines operating at 3000/sup 0/F, allowing for all auxiliary loads and losses, is 47.7 percent (HHV) representing a heat rate of 7160 Btu/Kw-Hr. (LCL)
  • Changes made to the preliminary design of a commercial combined cycle electric powerplant operating on low Btu gas fuel are described. Major elements changed were: gas turbine configuration; gas desulfurization system; gas cleanup system; and the steam system operating parameters. The net power output of this base load station was increased from 750 MW to 1032 MW, by increasing the size of the four gas turbines. The gas turbine configuration was changed from a 2-spool, annular burner arrangement to a single shaft engine with can-type combustors. Firing temperature is revised from 3000 to 2750/sup 0/F. The free power turbine arrangementmore » of the original powerplant concept which permits double-ending the electrical generators was retained. The steam system configuration is changed from an 1800/1000 single level system to a 2400/1000/1000 single reheat configuration which utilizes heat extraction from the hot flue gas down to 280/sup 0/F, delivers gasifier steam and jacket water and provides fuel gas preheat. The steam system produces 376.MW of electrical power. The high temperature gas desulfurization and cleanup system of the original powerplant design is replaced by a cold water wash and a commercial Selexol desulfurization unit. This change produced a substantial reduction in overall powerplant efficiency, but was necessary because the previously-used developmental hot gas cleanup system has not advanced to commercial status. The Lurgi fixed bed gasifier utilized in the original powerplant concept was retained. The modular arrangement of the original powerplant design was retained. The overall powerplant coal pile to bus bar efficiency is 40.5%, conservatively based on demonstrated performance of individual commercial or near-commercial components utilized in the design.« less
  • General Electric's low-Btu coal-gas combined-cycle power plant offers improved operating flexibility, reliability, and efficiency over earlier designs. The power plant consists of four high-temperature, water-cooled PRD-6 gas turbines that burn coal-derived fuel gas and a steam bottoming cycle with one reheat steam turbine. The PRD-6 turbine has a 12:1 pressure ratio, a compressor inlet-air flow of 300 lb/s, and a 2600/sup 0/F firing temperature. The overall plant design has the following performance characteristics: (1) coal consumption of 313,848 lb/hr at 10,788 Btu/lb HHV (Illinois No. 6, as received), (2) gas turbine output of 277,200 kW (69,300 kW/turbine), (3) steam turbinemore » output of 140,200 kW, (4) net plant output of 406,900 kW, and (5) net thermal efficiency (HHV) of 41.02% (coal pile to bus bar). In the gasification plant's water-cooled fixed-bed coal gasifier, the partial oxidation of coal produces a combustible off-gas that is cleaned and fed to the turbines.« less
  • A promising method for increasing baseload efficiency using coal-derived fuels is through the use of an advanced design combined gas turbine-steam turbine system integrated with a low Btu gasifier. To achieve a high level of efficiency it is necessary to increase the gas turbine inlet temperatures to values of 2600 to 3000/sup 0/F and to adapt the gas turbine to the coal derived fuel environment. The design of a combined cycle generating system for operation on low Btu coal gas with the following objectives is presented: (1) increased baseload plant efficiency; (2) high temperature turbine operation; (3) optimum utilization ofmore » exhaust gas energy; (4) environmentally acceptable operation; and (5) high degree of reliability, maintainability and availability.« less