Design and raytrace simulations of a multilayer-coated Wolter x-ray optic for the Z machine at Sandia National Laboratories
Journal Article
·
· Review of Scientific Instruments
more »
- Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- Sandia National Laboratories, Albuquerque, New Mexico 87123, USA
- Smithsonian Astrophysical Observatory, Cambridge, MA (United States)
- Univ. Space Research Association, Huntsville, AL (United States)
- Universities Space Research Association, Huntsville, Alabama 35805, USA
- NASA Marshall Space Flight Center (MSFC), Huntsville, AL (United States)
Recent breakthroughs in the fabrication of small-radii Wolter optics for astrophysics allow high energy density facilities to consider such optics as novel x-ray diagnostics at photon energies of 15-50 keV. Recently, the Lawrence Livermore National Laboratory, Sandia National Laboratories (SNL), the Smithsonian Astrophysical Observatory, and the NASA Marshall Space Flight Center jointly developed and fabricated the first custom Wolter microscope for implementation in SNL’s Z machine with optimized sensitivity at 17.5 keV. To achieve spatial resolution of order 100-200 microns over a field of view of 5 × 5 × 5 mm3 with high throughput and narrow energy bandpass, the geometry of the optic and its multilayer required careful design and optimization. While the geometry mainly influences resolution and the field of view of the diagnostic, the mirror coating determines the spectral response and throughput. Here in this paper, we outline the details of the design and fabrication process for the first multilayer-coated Wolter I optic for SNL’s Z machine (Z Wolter), including its W/Si multilayer, and present results of raytrace simulations completed to predict and verify the performance of the optic.
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE; USDOE National Nuclear Security Administration (NNSA)
- Grant/Contract Number:
- AC52-07NA27344; NA0003525
- OSTI ID:
- 1488787
- Alternate ID(s):
- OSTI ID: 1476125
- Report Number(s):
- LLNL-JRNL--750575; 935859
- Journal Information:
- Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 89; ISSN 0034-6748
- Publisher:
- American Institute of Physics (AIP)Copyright Statement
- Country of Publication:
- United States
- Language:
- English
Characterization and calibration of a multilayer coated Wolter optic for an imager on the Z-machine at Sandia National Laboratories
|
journal | October 2018 |
A Wolter imager on the Z machine to diagnose warm x-ray sources
|
journal | October 2018 |
Similar Records
Characterization and calibration of a multilayer coated Wolter optic for an imager on the Z-machine at Sandia National Laboratories
A Wolter imager on the Z machine to diagnose warm x-ray sources
Characterization of multilayer coated replicated Wolter optics for imaging x-ray emission from pulsed power
Journal Article
·
Wed Oct 03 20:00:00 EDT 2018
· Review of Scientific Instruments
·
OSTI ID:1488808
A Wolter imager on the Z machine to diagnose warm x-ray sources
Journal Article
·
Wed Oct 03 20:00:00 EDT 2018
· Review of Scientific Instruments
·
OSTI ID:1488781
Characterization of multilayer coated replicated Wolter optics for imaging x-ray emission from pulsed power
Journal Article
·
Mon Aug 28 20:00:00 EDT 2017
· Proceedings of SPIE - The International Society for Optical Engineering
·
OSTI ID:1429840