skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Design and raytrace simulations of a multilayer-coated Wolter x-ray optic for the Z machine at Sandia National Laboratories

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.5038811· OSTI ID:1488787
 [1]; ORCiD logo [1];  [1];  [1];  [1];  [1];  [1];  [1];  [1]; ORCiD logo [1]; ORCiD logo [2];  [3];  [2]; ORCiD logo [2];  [2];  [2];  [2]; ORCiD logo [4];  [4];  [4] more »;  [5];  [6];  [7] « less
  1. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
  2. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
  3. Sandia National Laboratories, Albuquerque, New Mexico 87123, USA
  4. Smithsonian Astrophysical Observatory, Cambridge, MA (United States)
  5. Univ. Space Research Association, Huntsville, AL (United States)
  6. Universities Space Research Association, Huntsville, Alabama 35805, USA
  7. NASA Marshall Space Flight Center (MSFC), Huntsville, AL (United States)

Recent breakthroughs in the fabrication of small-radii Wolter optics for astrophysics allow high energy density facilities to consider such optics as novel x-ray diagnostics at photon energies of 15-50 keV. Recently, the Lawrence Livermore National Laboratory, Sandia National Laboratories (SNL), the Smithsonian Astrophysical Observatory, and the NASA Marshall Space Flight Center jointly developed and fabricated the first custom Wolter microscope for implementation in SNL’s Z machine with optimized sensitivity at 17.5 keV. To achieve spatial resolution of order 100-200 microns over a field of view of 5 × 5 × 5 mm3 with high throughput and narrow energy bandpass, the geometry of the optic and its multilayer required careful design and optimization. While the geometry mainly influences resolution and the field of view of the diagnostic, the mirror coating determines the spectral response and throughput. Here in this paper, we outline the details of the design and fabrication process for the first multilayer-coated Wolter I optic for SNL’s Z machine (Z Wolter), including its W/Si multilayer, and present results of raytrace simulations completed to predict and verify the performance of the optic.

Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC52-07NA27344; NA0003525
OSTI ID:
1488787
Alternate ID(s):
OSTI ID: 1476125
Report Number(s):
LLNL-JRNL-750575; 935859
Journal Information:
Review of Scientific Instruments, Vol. 89, Issue 10; ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)Copyright Statement
Country of Publication:
United States
Language:
English
Citation Metrics:
Cited by: 7 works
Citation information provided by
Web of Science

References (15)

Spiegelsysteme streifenden Einfalls als abbildende Optiken für Röntgenstrahlen journal January 1952
Development of hard x-ray optics at MSFC conference March 2003
High energy X-ray pinhole imaging at the Z facility journal June 2016
Progress of focusing x-ray and gamma-ray optics for small animal imaging conference September 2005
Monochromatic x-ray backlighting of wire-array z -pinch plasmas using spherically bent quartz crystals journal March 2003
Characterization of multilayer coated replicated Wolter optics for imaging x-ray emission from pulsed power conference September 2017
Contrasting physics in wire array z pinch sources of 1-20 keV emission on the Z facility journal May 2014
The Focusing Optics X-ray Solar Imager (FOXSI) conference September 2011
A Wolter imager on the Z machine to diagnose warm x-ray sources journal October 2018
The National Ignition Facility modular Kirkpatrick-Baez microscope journal August 2016
Development of light weight replicated x-ray optics conference October 2013
Demonstration of a novel focusing small-angle neutron scattering instrument equipped with axisymmetric mirrors journal September 2013
An x-ray optic calibration facility for high energy density diagnostics journal October 2018
Characterization and calibration of a multilayer coated Wolter optic for an imager on the Z-machine at Sandia National Laboratories journal October 2018
Demonstration of a novel focusing small-angle neutron scattering instrument equipped with axisymmetric mirrors text January 2013

Cited By (2)

Characterization and calibration of a multilayer coated Wolter optic for an imager on the Z-machine at Sandia National Laboratories journal October 2018
A Wolter imager on the Z machine to diagnose warm x-ray sources journal October 2018

Similar Records

Design and simulation of multilayer coatings for a multi-channel Wolter-like x-ray imager with large field of view and high resolution
Journal Article · Tue Oct 03 00:00:00 EDT 2023 · Review of Scientific Instruments · OSTI ID:1488787

Characterization and calibration of a multilayer coated Wolter optic for an imager on the Z-machine at Sandia National Laboratories
Journal Article · Thu Oct 04 00:00:00 EDT 2018 · Review of Scientific Instruments · OSTI ID:1488787

Characterization of multilayer coated replicated Wolter optics for imaging x-ray emission from pulsed power
Journal Article · Tue Aug 29 00:00:00 EDT 2017 · Proceedings of SPIE - The International Society for Optical Engineering · OSTI ID:1488787