Enhanced Component Performance Study: Motor-Operated Valves 1998–2014

Technical Report ·
DOI:https://doi.org/10.2172/1482989· OSTI ID:1482989
 [1]
  1. Idaho National Lab. (INL), Idaho Falls, ID (United States)
This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The MOV failure modes considered are failure to open/close, failure to operate or control, and spurious operation. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. One statistically significant trend was observed in the data: The frequency of demands per reactor year for valves with fail-to-open/close failure modes, for valves with greater than twenty demands per year, was found to be decreasing.
Research Organization:
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC07-05ID14517
OSTI ID:
1482989
Report Number(s):
INL/EXT--15-36479-Rev000
Country of Publication:
United States
Language:
English

Similar Records

Enhanced Component Performance Study: Motor-Operated Valves 1998–2013
Technical Report · Sat Jan 31 23:00:00 EST 2015 · OSTI ID:1482985

Enhanced Component Performance Study: Air-Operated Valves 1998-2014
Technical Report · Sun Nov 01 00:00:00 EDT 2015 · OSTI ID:1260457

Enhanced Component Performance Study: Motor-Operated Valves 1998-2020
Technical Report · Mon Feb 28 23:00:00 EST 2022 · OSTI ID:1894881