Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Enhanced Component Performance Study: Motor-Operated Valves 1998-2020

Technical Report ·
DOI:https://doi.org/10.2172/1894881· OSTI ID:1894881
This report presents an enhanced performance evaluation of motor-operated valves (MOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from calendar year 1998 through 2020 as reported in the Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS). The MOV failure modes considered are fail to open or close (FTOC), fail to operate or control (FTOP), and spurious operation (SO). The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire study period. The following increasing trend was identified for MOVs for the most recent 10-year period: • Low-demand MOV frequency of FTOC demands (demands per reactor year). The following increasing trends were identified for MOVs for the most recent 10-year period: • Low-demand MOV FTOC failure probability • Low-demand MOV frequency of FTOC events (failures per reactor year).
Research Organization:
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
Sponsoring Organization:
USDOE Office of Nuclear Energy (NE)
DOE Contract Number:
AC07-05ID14517
OSTI ID:
1894881
Report Number(s):
INL/RPT-22-66600-Rev.0
Country of Publication:
United States
Language:
English

Similar Records

Enhanced Component Performance Study: Motor Operated Valves 1998–2022
Technical Report · Sat Jul 01 00:00:00 EDT 2023 · OSTI ID:2301605

Enhanced Component Performance Study: Air Operated Valves 1998–2022
Technical Report · Sat Jul 01 00:00:00 EDT 2023 · OSTI ID:2301609

Enhanced Component Performance Study: Air-Operated Valves 1998–2020
Technical Report · Mon Feb 28 23:00:00 EST 2022 · OSTI ID:1894684