Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Conceptual Design of an Improved Sodium Plugging Loop

Technical Report ·
DOI:https://doi.org/10.2172/1480504· OSTI ID:1480504
 [1];  [1]
  1. Argonne National Lab. (ANL), Argonne, IL (United States)
Based upon lessons learned in operating the initial sodium portion of the Sodium Plugging Phenomena Loop that itself became plugged and could not be unplugged, a set of improved design features have been identified for a new sodium loop that is less prone to inadvertent plugging. The new design features include a new sodium vessel that combines the functionalities of an expansion tank and a cold trap, increasing the loop tubing diameter/size, improving the thermal designs of the pump and flow meter, improved heater zoning, and an improved temperature distribution strategy along the loop. A new plugging loop conceptual design implementing these features has been developed.
Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Basic Energy Sciences (BES) (SC-22)
DOE Contract Number:
AC02-06CH11357
OSTI ID:
1480504
Report Number(s):
ANL-ART--128; 143728
Country of Publication:
United States
Language:
English

Similar Records

SODIUM RESISTIVITY METER LOOP. Summary Report, December 1963
Technical Report · Fri Oct 30 23:00:00 EST 1964 · OSTI ID:4106192

Experimental investigations on sodium plugging in narrow flow channels.
Journal Article · Sun Aug 01 00:00:00 EDT 2010 · Nucl. Technol. · OSTI ID:989068

Analysis and methodology for measuring oxygen concentration in liquid sodium with a plugging meter
Conference · Sun Jul 01 00:00:00 EDT 2012 · OSTI ID:22105989