MLEP-Fail Calibration for 1/8 inch thick plate of 13-8 PH steel in the H1150 condition
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
The purpose of the work presented in this memo was to calibrate the Sierra material model Multilinear Elastic-Plastic Hardening Model with Failure, (MLEP-Fail), for 1/8 inch thick plate of 13-8 PH steel in the H1150 condition. Material testing was pursued first, followed by the actual calibration.
- Research Organization:
- Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1462920
- Report Number(s):
- SAND--2017-13158R; 666489
- Country of Publication:
- United States
- Language:
- English