Thermal safety characterization on PETN, PBX-9407, LX-10-2, LX-17-1 and detonator in the LLNL's P-ODTX system

Technical Report ·
DOI:https://doi.org/10.2172/1396199· OSTI ID:1396199
 [1];  [1];  [1];  [1];  [1];  [1]
  1. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Incidents caused by fire and other thermal events can heat energetic materials that may lead to thermal explosion and result in structural damage and casualty. Thus, it is important to understand the response of energetic materials to thermal insults. The One-Dimensional-Time to Explosion (ODTX) system at the Lawrence Livermore National Laboratory (LLNL) has been used for decades to characterize thermal safety of energetic materials. In this study, an integration of a pressure monitoring element has been added into the ODTX system (P-ODTX) to perform thermal explosion (cook-off) experiments (thermal runaway) on PETN powder, PBX-9407, LX-10-2, LX-17-1, and detonator samples (cup tests). The P-ODTX testing generates useful data (thermal explosion temperature, thermal explosion time, and gas pressures) to assist with the thermal safety assessment of relevant energetic materials and components. This report summarizes the results of P-ODTX experiments that were performed from May 2015 to July 2017. Recent upgrades to the data acquisition system allows for rapid pressure monitoring in microsecond intervals during thermal explosion. These pressure data are also included in the report.
Research Organization:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC52-07NA27344
OSTI ID:
1396199
Report Number(s):
LLNL--TR-739143
Country of Publication:
United States
Language:
English

Similar Records

ONE-DIMENSIONAL TIME TO EXPLOSION (THERMAL SENSITIVITY) TESTS ON PETN, PBX-9407, LX-10, AND LX-17
Technical Report · Wed Jan 27 23:00:00 EST 2016 · OSTI ID:1237577

Cook-off Study and Gas Pressure Measurement on HMX, LX-07, PBX 9502, and XTX-8004 in the P-ODTX System
Technical Report · Wed Mar 27 00:00:00 EDT 2019 · OSTI ID:1544926

Thermal Safety Characterization of HMX, LX-07, PBX 9502, and XTX-8004 in the ODTX System
Technical Report · Thu Aug 23 00:00:00 EDT 2018 · OSTI ID:1544925