The V27 containment vessel was procured by the US Army Recovered Chemical Material Directorate ( RCMD ) as a replacement vessel for use on the P2 Explosive Destruction Systems. It is the third EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the Code Case, is nine (9) pounds TNT - equivalent for up to 637 detonations . This report documents the results of explosive tests that were done on the vessel at Sandia National Laboratories in Albuquerque New Mexico to qualify the vessel for explosive use . The primary qualification test consisted of si x 1.5 pound charges of Composition C - 4 (equivalent to 11.25 pounds TNT) distributed around the vessel in accordance with the User Design Specification. Four subsequent tests using less explosive evaluated the effects of slight variations in orientation of the charges . All vessel acceptance criteria were met.
Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Sandia National Laboratories, Livermore, CA
Sponsoring Organization:
US Army Recovered Chemical Material Directorate; USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
1367411
Report Number(s):
SAND--2017-4840; 653117
Country of Publication:
United States
Language:
English

Similar Records

V28 Test Report
Technical Report · Fri Jan 31 23:00:00 EST 2020 · OSTI ID:1600620

EDS V25 Containment Vessel Explosive Qualification Test Report
Technical Report · Sat Mar 31 20:00:00 EDT 2012 · OSTI ID:1048495

EDS V26 Vessel Clamp Explosive Test Report
Technical Report · Tue Aug 01 00:00:00 EDT 2017 · OSTI ID:1761810