Thermocouple Errors when Mounted on Cylindrical Surfaces in Abnormal Thermal Environments.
- Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
- ECI Inc., Albuquerque, NM (United States)
Mineral-insulated, metal-sheathed, Type-K thermocouples are used to measure the temperature of various items in high-temperature environments, often exceeding 1000degC (1273 K). The thermocouple wires (chromel and alumel) are protected from the harsh environments by an Inconel sheath and magnesium oxide (MgO) insulation. The sheath and insulation are required for reliable measurements. Due to the sheath and MgO insulation, the temperature registered by the thermocouple is not the temperature of the surface of interest. In some cases, the error incurred is large enough to be of concern because these data are used for model validation, and thus the uncertainties of the data need to be well documented. This report documents the error using 0.062" and 0.040" diameter Inconel sheathed, Type-K thermocouples mounted on cylindrical surfaces (inside of a shroud, outside and inside of a mock test unit). After an initial transient, the thermocouple bias errors typically range only about +-1-2% of the reading in K. After all of the uncertainty sources have been included, the total uncertainty to 95% confidence, for shroud or test unit TCs in abnormal thermal environments, is about +-2% of the reading in K, lower than the +-3% typically used for flat shrouds. Recommendations are provided in Section 6 to facilitate interpretation and use of the results. .
- Research Organization:
- Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 1367399
- Report Number(s):
- SAND--2017-4722; 653026
- Country of Publication:
- United States
- Language:
- English
Similar Records
Quantitative SIMS analysis of decalibrated Chromel versus Alumel thermocouples using indexed sensitivity factors
THERMOCOUPLE DESIGN AND TEST PROGRAM FOR REACTOR PROJECTS
Uncertainty analysis of thermocouple measurements used in normal and abnormal thermal environment experiments at Sandia's Radiant Heat Facility and Lurance Canyon Burn Site.
Conference
·
Sun Dec 31 23:00:00 EST 1978
·
OSTI ID:6033749
THERMOCOUPLE DESIGN AND TEST PROGRAM FOR REACTOR PROJECTS
Technical Report
·
Fri May 01 00:00:00 EDT 1959
·
OSTI ID:4274124
Uncertainty analysis of thermocouple measurements used in normal and abnormal thermal environment experiments at Sandia's Radiant Heat Facility and Lurance Canyon Burn Site.
Technical Report
·
Wed Mar 31 23:00:00 EST 2004
·
OSTI ID:918777