We investigated three algorithms for discriminating between neutrons and gamma rays in a pres-surized 4He gas fast neutron detector: charge comparison, weighted integration, and neutron-gamma model analysis (NGMA). And for each algorithm, a comprehensive pulse shape discrimination study was conducted using time-of-flight measurements, receiver operator characteristic curves, figure of merit performance measures, and a comparison of performance between 252Cf and PuBe mixed neutron/gamma sources. The NGMA method was found to have the best overall performance by both the figure of merit and the receiver operator characteristic curve. Our results also illustrated the high gamma rejection efficiency of these detectors, which is desirable in a variety of neutron monitoring applications.
Research Organization:
Univ. of Michigan, Ann Arbor, MI (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Nonproliferation and Verification Research and Development (NA-22)
Grant/Contract Number:
NA0002534
OSTI ID:
1366968
Alternate ID(s):
OSTI ID: 22564955
Journal Information:
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Journal Issue: C Vol. 830; ISSN 0168-9002
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

Similar Records

Neutron and Gamma Ray Pulse Shape Discrimination with Polyvinyltoluene
Technical Report · Wed Feb 29 23:00:00 EST 2012 · OSTI ID:1059208

Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers
Journal Article · Thu May 07 20:00:00 EDT 2015 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1365799

Comparison of analog and digital pulse-shape-discrimination systems
Journal Article · Fri Mar 25 20:00:00 EDT 2016 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1366592