Comparison of analog and digital pulse-shape-discrimination systems
Journal Article
·
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Univ. of Michigan, Ann Arbor, MI (United States); Department of Nuclear Engineering and Radiological Sciences, University of Michigan
- Univ. of Michigan, Ann Arbor, MI (United States)
Pulse shape discrimination (PSD) performance of two optimized PSD systems (one digital and one analog) is compared in this work. One system uses digital charge integration, while the other system uses analog zero crossing. Measurements were conducted with each PSD system using the CAEN V1720 (250 MHz) data acquisition system. An organic-liquid scintillator, coupled to a photo-multiplier tube, was used to detect neutrons and gamma rays from a Cf-252 spontaneous-fission source. The PSD perfor-mance of both systems was optimized and quantified using a traditional figure-of-merit (FOM) approach. FOM's were found for three, 300 keVee light-output bins, spanning from 100 to 1000 keVee, and one larger bin from 100 to 1800 keVee. Digital PSD outperformed analog PSD in the lowest light-output bin by approximately 50%, and by 11% for the highest light-output bin.
- Research Organization:
- Univ. of Michigan, Ann Arbor, MI (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA)
- Grant/Contract Number:
- NA0002534
- OSTI ID:
- 1366592
- Alternate ID(s):
- OSTI ID: 1359648
OSTI ID: 22564823
- Journal Information:
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment, Journal Name: Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment Vol. 826; ISSN 0168-9002
- Publisher:
- ElsevierCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pulse shape discrimination performance of stilbene coupled to low-noise silicon photomultipliers
Digital front-end electronics for a tagged neutron inspection system
Neutron detection in a high gamma ray background with liquid scintillators
Journal Article
·
Thu May 07 20:00:00 EDT 2015
· Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
·
OSTI ID:1365799
Digital front-end electronics for a tagged neutron inspection system
Journal Article
·
Fri Apr 19 00:00:00 EDT 2013
· AIP Conference Proceedings
·
OSTI ID:22116964
Neutron detection in a high gamma ray background with liquid scintillators
Journal Article
·
Fri Apr 19 00:00:00 EDT 2013
· AIP Conference Proceedings
·
OSTI ID:22117030