Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Results of four one-day electron-accelerator irradiations of enriched Mo-100 targets for the production of Mo-99

Technical Report ·
DOI:https://doi.org/10.2172/1342160· OSTI ID:1342160
A series of four one-day irradiations was conducted with 100Mo-enriched disk targets. After irradiation, the enriched disks were removed from the target and dissolved. The resulting solution was processed using a NorthStar RadioGenix™ 99mTc generator either at Argonne National Laboratory or at the NorthStar Medical Radioisotopes facility. Runs on the RadioGenix system produced inconsistent analytical results for 99mTc in the Tc/Mo solution. These inconsistencies were attributed to the impurities in the solution or improper column packing. During the irradiations, the performance of the optic transitional radiation (OTR) and infrared cameras was tested in high radiation field. The OTR cameras survived all irradiations, while the IR cameras failed every time. The addition of X-ray and neutron shielding improved camera survivability and decreased the number of upsets.
Research Organization:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation (NA-20)
DOE Contract Number:
AC02-06CH11357
OSTI ID:
1342160
Report Number(s):
ANL/NE--16/26; 132736
Country of Publication:
United States
Language:
English