Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Assay Methods for 238U, 232Th, and 210Pb in Lead and Calibration of 210Bi Bremsstrahlung Emission from Lead

Journal Article · · Journal of Radioanalytical and Nuclear Chemistry
Assay methods for measuring 238U, 232Th, and 210Pb concentrations in refined lead are presented. The 238U and 232Th concentrations are assayed via inductively coupled plasma mass spectrometry (ICP-MS) after anion exchange column separation on dissolved lead samples. The 210Pb concentration is inferred through α-spectroscopy of a daughter isotope, 210Po, after chemical precipitation separation on dissolved lead samples. Subsequent to the 210Po α-spectroscopy assay, a method for evaluating 210Pb concentrations in solid lead samples was developed via measurement of bremsstrahlung radiation from β-decay of a daughter isotope, 210Bi, by employing a 14-crystal array of high purity germanium (HPGe) detectors. Ten sources of refined lead were assayed. The 238U concentrations were <34 microBq/kg and the 232Th concentrations ranged <0.6 – 15 microBq/kg, as determined by the ICP-MS assay method. The 210Pb concentrations ranged from ~0.1 – 75 Bq/kg, as inferred by the 210Po α-spectroscopy assay method.
Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1331735
Report Number(s):
PNNL-SA-115123
Journal Information:
Journal of Radioanalytical and Nuclear Chemistry, Journal Name: Journal of Radioanalytical and Nuclear Chemistry Journal Issue: 3 Vol. 309; ISSN 0236-5731
Publisher:
Springer
Country of Publication:
United States
Language:
English

Similar Records

Behavior of the 222Rn daughters on copper surfaces during cleaning
Journal Article · Wed Mar 28 00:00:00 EDT 2007 · AIP Conference Proceedings · OSTI ID:21055028

Use of Electrodeposition for Sample Preparation and Rejection Rate Prediction for Assay of Electroformed Ultra High Purity Copper for 232Th and 238U Prior to Inductively Coupled Plasma Mass Spectrometry (ICP/MS)
Journal Article · Tue Jul 01 00:00:00 EDT 2008 · Journal of Radioanalytical and Nuclear Chemistry, 277(1):103-110 · OSTI ID:949103

Separation of 210-Bi and 210-Po by using ion-exchange membrane filters: Environmental applications
Conference · Tue Dec 30 23:00:00 EST 1997 · OSTI ID:560316

Related Subjects