Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Boiler tube failures in municipal waste-to-energy plants: Case histories

Conference ·
OSTI ID:128729
;  [1]
  1. Battelle, Columbus, OH (United States)

Waste-to-energy plants experienced boiler tube failures when the design changed from waste-heat boilers to radiant furnace waterwalls with superheat, adopted from coal-firing technology. The fireside attack by chlorine and sulfur compounds in the refuse combustion products caused many forced outages in early European plants with high steam temperatures and pressures. In spite of conservative steam conditions in the first US plants, some failures occurred. As steam temperatures increased in later US plants, corrosion problems multiplied. Over the years these problems have been alleviated by covering the waterwalls with either refractories or weld overlays of nickel-base alloys and using high nickel-chromium alloys for superheater tubes. Various changes in furnace design to provide uniform combustion and avoid reducing conditions in the waterwall zone and to lower the gas temperature in the superheater also have helped to minimize corrosion.

OSTI ID:
128729
Report Number(s):
CONF-950304--
Country of Publication:
United States
Language:
English

Similar Records

Boiler tube failures in municipal waste-to-energy plants
Journal Article · Sun Dec 31 23:00:00 EST 1995 · Materials Performance · OSTI ID:170018

Fireside corrosion problems in refuse-fired boilers
Journal Article · Mon Feb 28 23:00:00 EST 1994 · Materials Performance; (United States) · OSTI ID:5096087

Incinerating municipal and industrial waste
Conference · Mon Dec 31 23:00:00 EST 1990 · OSTI ID:5377544