Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Technical Basis for Evaluating Software-Related Common-Cause Failures

Technical Report ·
DOI:https://doi.org/10.2172/1279406· OSTI ID:1279406
 [1];  [2]
  1. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
  2. Univ. of Tennessee, Knoxville, TN (United States); Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
The instrumentation and control (I&C) system architecture at a nuclear power plant (NPP) incorporates protections against common-cause failures (CCFs) through the use of diversity and defense-in-depth. Even for well-established analog-based I&C system designs, the potential for CCFs of multiple systems (or redundancies within a system) constitutes a credible threat to defeating the defense-in-depth provisions within the I&C system architectures. The integration of digital technologies into the I&C systems provides many advantages compared to the aging analog systems with respect to reliability, maintenance, operability, and cost effectiveness. However, maintaining the diversity and defense-in-depth for both the hardware and software within the digital system is challenging. In fact, the introduction of digital technologies may actually increase the potential for CCF vulnerabilities because of the introduction of undetected systematic faults. These systematic faults are defined as a “design fault located in a software component” and at a high level, are predominately the result of (1) errors in the requirement specification, (2) inadequate provisions to account for design limits (e.g., environmental stress), or (3) technical faults incorporated in the internal system (or architectural) design or implementation. Other technology-neutral CCF concerns include hardware design errors, equipment qualification deficiencies, installation or maintenance errors, instrument loop scaling and setpoint mistakes.
Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE; US Nuclear Regulatory Commission (NRC)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1279406
Report Number(s):
ORNL/SR--2016/130; 453040374
Country of Publication:
United States
Language:
English

Similar Records

Common Cause Failure Mitigation Experience on Digital I and C System in NPP
Journal Article · Fri Jul 01 00:00:00 EDT 2016 · Transactions of the American Nuclear Society · OSTI ID:23042613

NRC technical basis for evaluation of its position on protection against common cause failure in digital systems used in nuclear power plants - 378
Conference · Thu Jun 15 00:00:00 EDT 2017 · OSTI ID:23035463

Analyzing Hardware and Software Common Cause Failures in Digital Instrumentation and Control Systems using Dual Error Propagation Method
Conference · Sun Jul 16 20:00:00 EDT 2023 · OSTI ID:2004909