Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Monitoring the 1 {Omega} standard resistor by quantum Hall effect

Conference ·
OSTI ID:125741
; ;  [1]
  1. Electrotechnical Lab., Ibaraki (Japan); and others

Resistance standards at ETL are maintained by quantum Hall effect. Resistance of the 1 {Omega} resistor named 69J101 is monitored. The result is R{sub 69J101} = 1 - (6.682 {+-} 0.018) x 10{sup -6} + (0.110 {+-} 0.003) x 10{sup -6} t {Omega} where t is time in years from January 1, 1994. The difference of 1 {Omega} standard between ETL and BIPM on 1990 international comparison is reduced from -0.128 ppm to -0.044 ppm.

OSTI ID:
125741
Report Number(s):
CONF-940603--
Country of Publication:
United States
Language:
English

Similar Records

A Comparison of 1 T(Omega) and 10 T (Omega) High Resistance Standards Between NIST and Sandia
Conference · Fri Apr 23 00:00:00 EDT 1999 · OSTI ID:5950

Determination of the time-dependence of. Omega. /sub NBS/ using the quantized Hall resistance
Journal Article · Fri Mar 31 23:00:00 EST 1989 · IEEE (Institute of Electrical and Electronics Engineers) Transactions on Instrumentation and Measurement; (USA) · OSTI ID:5147614

Comparison of quantum Hall effect resistance standards of the BNM/LCIE and the BIPM