Procedures for Calculating Residential Dehumidification Loads
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Building Technologies Office (EE-5B)
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1256677
- Report Number(s):
- NREL/TP--5500-66515
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates
Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates
Transient dehumidification characteristics of a heat pump in cooling mode
Technical Report
·
Wed Oct 01 00:00:00 EDT 2014
·
OSTI ID:1220346
Measure Guideline: Supplemental Dehumidification in Warm-Humid Climates
Technical Report
·
Wed Oct 01 00:00:00 EDT 2014
·
OSTI ID:1160177
Transient dehumidification characteristics of a heat pump in cooling mode
Journal Article
·
Thu Oct 31 23:00:00 EST 1991
· Journal of Solar Energy Engineering; (United States)
·
OSTI ID:5861994