Statistical Distributions from Lens Manufacturing Data
Conference
·
· Proc. SPIE 9195, Optical System Alignment, Tolerancing, and Verification VIII, 919507 (19 September 2014); doi: 10.1117/12.2064582
OSTI ID:1246344
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Optimax Systems
Optical designers assume a mathematically derived statistical distribution of the relevant design parameters for their Monte Carlo tolerancing simulation. Presented are measured distributions using lens manufacturing data to better inform the decision-making process.
- Research Organization:
- Nevada Test Site/National Security Technologies, LLC (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA), Office of Defense Programs (DP) (NA-10)
- DOE Contract Number:
- AC52-06NA25946
- OSTI ID:
- 1246344
- Report Number(s):
- DOE/NV/25946--2133
- Conference Information:
- Journal Name: Proc. SPIE 9195, Optical System Alignment, Tolerancing, and Verification VIII, 919507 (19 September 2014); doi: 10.1117/12.2064582 Journal Volume: 9195
- Country of Publication:
- United States
- Language:
- English
Similar Records
Techniques for Analyzing Lens Manufacturing Data with Optical Design Applications
High-Resolution UV Relay Lens for Particle Size Distribution Measurements Using Holography
High-Resolution UV Relay Lens for Particle Size Distribution Measurements Using Holography
Conference
·
Sat Aug 01 00:00:00 EDT 2015
· Proc. SPIE 9573, Optomechanical Engineering 2015, 95730M (September 2, 2015); doi:10.1117/12.2186451
·
OSTI ID:1240355
High-Resolution UV Relay Lens for Particle Size Distribution Measurements Using Holography
Conference
·
Fri Feb 29 23:00:00 EST 2008
·
OSTI ID:926229
High-Resolution UV Relay Lens for Particle Size Distribution Measurements Using Holography
Conference
·
Fri Aug 29 00:00:00 EDT 2008
· Proceedings SPIE
·
OSTI ID:939690