Evaluation of cathodic protection system design for tanks with double bottoms utilizing galvanic anodes

Book ·
OSTI ID:124415
 [1];  [2]
  1. Mobil Research and Development Corp., Paulsboro, NJ (United States)
  2. Mobil Beaumont Refinery, TX (United States)

An investigation was conducted on the performance of two different cathodic protection systems designs utilizing zinc ribbon anodes that can be used for corrosion control for aboveground storage tanks with double bottoms. A full scale field test on a 35 meter (115 feet) diameter tank was conducted to determine cathodic protection system performance. The test included periodic measurement of tank bottom steel potentials including on, instant off and polarization decay, anode current output with associated current densities and tank product level measurements. Results showed that zinc ribbon anode spacing in a chord fashion of 1.2 meter (4 feet) or less can be effective to achieve cathodic protection according to industry accepted standards.

OSTI ID:
124415
Report Number(s):
CONF-950304--
Country of Publication:
United States
Language:
English

Similar Records

Aboveground storage tank double bottom cathodic protection
Book · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:378077

Evaluation of galvanic anodes: Cathodic protection design for double bottom tanks
Journal Article · Wed May 01 00:00:00 EDT 1996 · Materials Performance · OSTI ID:231152

Cathodic protection of above ground storage tanks with double bottoms or secondary containment
Conference · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:176042