Moisture Durability Assessment of Selected Well-insulated Wall Assemblies
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
This report presents the results from studying the hygrothermal performance of two well-insulated wall assemblies, both complying with and exceeding international building codes (IECC 2015 2014, IRC 2015). The hygrothermal performance of walls is affected by a large number of influential parameters (e.g., outdoor and indoor climates, workmanship, material properties). This study was based on a probabilistic risk assessment in which a number of these influential parameters were simulated with their natural variability. The purpose of this approach was to generate simulation results based on laboratory chamber measurements that represent a variety of performances and thus better mimic realistic conditions. In total, laboratory measurements and 6,000 simulations were completed for five different US climate zones. A mold growth indicator (MGI) was used to estimate the risk of mold which potentially can cause moisture durability problems in the selected wall assemblies. Analyzing the possible impact on the indoor climate due to mold was not part of this study. The following conclusions can be reached from analyzing the simulation results. In a hot-humid climate, a higher R-value increases the importance of the airtightness because interior wall materials are at lower temperatures. In a cold climate, indoor humidity levels increase with increased airtightness. Air leakage must be considered in a hygrothermal risk assessment, since air efficiently brings moisture into buildings from either the interior or exterior environment. The sensitivity analysis of this study identifies mitigation strategies. Again, it is important to remark that MGI is an indicator of mold, not an indicator of indoor air quality and that mold is the most conservative indicator for moisture durability issues.
- Research Organization:
- Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States). Building Technologies Research and Integration Center (BTRIC)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE)
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1238746
- Report Number(s):
- ORNL/TM--2015/645; BT0101000; CEBT114
- Country of Publication:
- United States
- Language:
- English
Similar Records
Prediction of hygrothermal performance of building envelope parts coupled with indoor climate
A Hygrothermal Risk Analysis Applied to Residential Unvented Attics
PROTOCOL TO EVALUATE THE MOISTURE DURABILITY OF ENERGY-EFFICIENT WALLS
Book
·
Wed Dec 30 23:00:00 EST 1998
·
OSTI ID:687654
A Hygrothermal Risk Analysis Applied to Residential Unvented Attics
Conference
·
Mon Dec 31 23:00:00 EST 2012
·
OSTI ID:1110964
PROTOCOL TO EVALUATE THE MOISTURE DURABILITY OF ENERGY-EFFICIENT WALLS
Conference
·
Thu Dec 31 23:00:00 EST 2015
·
OSTI ID:1355875