A Hygrothermal Risk Analysis Applied to Residential Unvented Attics
Conference
·
OSTI ID:1110964
- ORNL
Aresidential building, constructed with an unvented attic, is acommonroof assembly in the United States.The expected hygrothermal performance and service life of the roof are difficult to estimate due to a number of varying parameters.Typical parameters expected to vary are the climate, direction, and slope of the roof as well as the radiation properties of the surface material. Furthermore, influential parameters are indoor moisture excess, air leakages through the attic floor, and leakages from air-handling unit and ventilation ducts. In addition, the type of building materials such as the insulation material and closed or open cell spray polyurethane foam will influence the future performance of the roof. A development of a simulation model of the roof assembly will enable a risk and sensitivity analysis, in which the most important varying parameters on the hygrothermal performance can be determined. The model is designed to perform probabilistic simulations using mathematical and hygrothermal calculation tools. The varying input parameters can be chosen from existing measurements, simulations, or standards. An analysis is applied to determine the risk of consequences, such as mold growth, rot, or energy demand of the HVAC unit. Furthermore, the future performance of the roof can be simulated in different climates to facilitate the design of an efficient and reliable roof construction with the most suitable technical solution and to determine the most appropriate building materials for a given climate
- Research Organization:
- Oak Ridge National Laboratory (ORNL)
- Sponsoring Organization:
- EE USDOE - Office of Energy Efficiency and Renewable Energy (EE)
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1110964
- Country of Publication:
- United States
- Language:
- English
Similar Records
Thermal Performance of Unvented Attics in Hot-Dry Climates
Hygrothermal Performance of West Coast Wood Deck Roofing System
Indoor Climate and Moisture Durability Performances of Houses with Unvented Attic Roof Constructions in a Mixed-Humid Climate
Technical Report
·
Sun Mar 31 23:00:00 EST 2002
·
OSTI ID:15000301
Hygrothermal Performance of West Coast Wood Deck Roofing System
Technical Report
·
Fri Jan 31 23:00:00 EST 2014
·
OSTI ID:1126977
Indoor Climate and Moisture Durability Performances of Houses with Unvented Attic Roof Constructions in a Mixed-Humid Climate
Technical Report
·
Wed Oct 01 00:00:00 EDT 2014
·
OSTI ID:1185718