skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Shutdown Dose Rate Analysis Using the Multi-Step CADIS Method

Journal Article · · Fusion Science and Technology
DOI:https://doi.org/10.13182/FST15-123· OSTI ID:1214480

The Multi-Step Consistent Adjoint Driven Importance Sampling (MS-CADIS) hybrid Monte Carlo (MC)/deterministic radiation transport method was proposed to speed up the shutdown dose rate (SDDR) neutron MC calculation using an importance function that represents the neutron importance to the final SDDR. This work applied the MS-CADIS method to the ITER SDDR benchmark problem. The MS-CADIS method was also used to calculate the SDDR uncertainty resulting from uncertainties in the MC neutron calculation and to determine the degree of undersampling in SDDR calculations because of the limited ability of the MC method to tally detailed spatial and energy distributions. The analysis that used the ITER benchmark problem compared the efficiency of the MS-CADIS method to the traditional approach of using global MC variance reduction techniques for speeding up SDDR neutron MC calculation. Compared to the standard Forward-Weighted-CADIS (FW-CADIS) method, the MS-CADIS method increased the efficiency of the SDDR neutron MC calculation by 69%. The MS-CADIS method also increased the fraction of nonzero scoring mesh tally elements in the space-energy regions of high importance to the final SDDR.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1214480
Journal Information:
Fusion Science and Technology, Vol. 68, Issue 3; ISSN 1536-1055
Publisher:
American Nuclear SocietyCopyright Statement
Country of Publication:
United States
Language:
English

References (4)

SCALE 6: Comprehensive Nuclear Safety Analysis Code System journal May 2011
FW-CADIS Method for Global and Regional Variance Reduction of Monte Carlo Radiation Transport Calculations journal January 2014
Rigorous mcnp based shutdown dose rate calculations: computational scheme, verification calculations and application to ITER journal December 2002
Novel hybrid Monte Carlo/deterministic technique for shutdown dose rate analyses of fusion energy systems journal October 2014