Radiation-induced DNA damage and the relative biological effectiveness of 18F-FDG in wild-type mice
- McMaster Univ., Hamilton, ON (Canada); McMaster University
- McMaster Univ., Hamilton, ON (Canada)
Clinically, the most commonly used positron emission tomography (PET) radiotracer is the glucose analog 2-[18F] fluoro-2-deoxy-d-glucose (18F-FDG), however little research has been conducted on the biological effects of 18F-FDG injections. The induction and repair of DNA damage and the relative biological effectiveness (RBE) of radiation from 18F-FDG relative to 662 keV γ-rays were investigated. The study also assessed whether low-dose radiation exposure from 18F-FDG was capable of inducing an adaptive response. DNA damage to the bone marrow erythroblast population was measured using micronucleus formation and lymphocyte γH2A.X levels. To test the RBE of 18F-FDG, mice were injected with a range of activities of 18F-FDG (0–14.80 MBq) or irradiated with Cs-137 γ-rays (0–100 mGy). The adaptive response was investigated 24 h after the 18F-FDG injection by 1 Gy in vivo challenge doses for micronucleated reticulocyte (MN-RET) formation or 1, 2 and 4 Gy in vitro challenges doses for γH2A.X formation. A significant increase in MN-RET formation above controls occurred following injection activities of 3.70, 7.40 or 14.80 MBq (P < 0.001) which correspond to bone marrow doses of ~35, 75 and 150 mGy, respectively. Per unit dose, the Cs-137 radiation exposure induced significantly more damage than the 18F-FDG injections (RBE = 0.79 ± 0.04). A 20% reduction in γH2A.X fluorescence was observed in mice injected with a prior adapting low dose of 14.80 MBq 18F-FDG relative to controls (P < 0.019). A 0.74 MBq 18F-FDG injection, which gives mice a dose approximately equal to a typical human PET scan, did not cause a significant increase in DNA damage nor did it generate an adaptive response. Typical 18F-FDG injection activities used in small animal imaging (14.80 MBq) resulted in a decrease in DNA damage, as measured by γH2A.X formation, below spontaneous levels observed in control mice. Lastly, the 18F-FDG RBE was <1.0, indicating that the mixed radiation quality and/or low dose rate from PET scans is less damaging than equivalent doses of gamma radiation.
- Research Organization:
- McMaster Univ., Hamilton, ON (Canada)
- Sponsoring Organization:
- USDOE Office of Science (SC), Biological and Environmental Research (BER) (SC-23)
- Grant/Contract Number:
- FG02-07ER64343
- OSTI ID:
- 1196276
- Report Number(s):
- DOE-MAC--64343
- Journal Information:
- Mutagenesis, Journal Name: Mutagenesis Journal Issue: 4 Vol. 29; ISSN 0267-8357
- Publisher:
- Oxford University PressCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Biological Response of Positron Emission Tomography Scan Exposure and Adaptive Response in Humans
|
journal | November 2015 |
DNA double strand breaks, repair and apoptosis following 511 keV γ -rays exposure using 18 fluorine positron emitter: an in-vitro study
|
journal | October 2018 |
Low-dose or low-dose-rate ionizing radiation–induced bioeffects in animal models
|
journal | December 2016 |
Similar Records
Low-dose radiation from 18F-FDG PET does not increase cancer frequency or shorten latency but reduces kidney disease in cancer-prone Trp53+/- mice
Human radiation dosimetry of 6-[{sup 18}F]FDG predicted from preclinical studies
Estimated radiation dose to the newborn in FDG-PET studies
Journal Article
·
Tue May 27 20:00:00 EDT 2014
· Mutagenesis
·
OSTI ID:1196279
Human radiation dosimetry of 6-[{sup 18}F]FDG predicted from preclinical studies
Journal Article
·
Sat Mar 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22250968
Estimated radiation dose to the newborn in FDG-PET studies
Journal Article
·
Wed Jan 31 23:00:00 EST 1996
· Journal of Nuclear Medicine
·
OSTI ID:381135