A low-inductance multichannel gas current switch

Journal Article · · Instruments and Experimental Techniques
OSTI ID:115044
; ;  [1]
  1. St. Petersburg State Technical Univ. (Russian Federation); and others

One method of generating high pulsed currents is to discharge a capacitor battery through a load. Such devices operate efficiently using controlled switches with low energy losses when they are acting and they operate for wide ranges of charging voltages. In order to conduct energy to the load at the highest rate, the intrinsic inductance of the pulsed current generators and, hence, of all their components, including the dischargers, should be minimized. The switch operates over a wide range of voltages (35-50 kV) and steadily generates a seven-channel discharge with a current pulse height of up to 300 kA.

OSTI ID:
115044
Journal Information:
Instruments and Experimental Techniques, Journal Name: Instruments and Experimental Techniques Journal Issue: 2 Vol. 38; ISSN 0020-4412; ISSN INETAK
Country of Publication:
United States
Language:
English

Similar Records

High-current switch for capacitance batteries with microsecond response
Journal Article · Tue Aug 01 00:00:00 EDT 1995 · Instruments and Experimental Techniques · OSTI ID:133160

Performance of a 10 kV, 625 kA, 85 kJ energy discharge module utilizing a solid dielectric switch
Conference · Mon Dec 31 23:00:00 EST 1990 · OSTI ID:5343549

Reversing-counterpulse repetitive-pulse inductive storage circuit