Radiolytic Stability of the ABEC Column
- Argonne National Laboratory (ANL), Argonne, IL (United States)
A key reagent of the TechneGen generator (NorthStar) is an ABEC (aqueous biphasic extraction chromatographic) column that consists of polyethylene glycol (PEG) bonded to a polystyrene-divinylbenzene co-polymer bead. The ABEC column is highly selective for the pertechnetate ion under highly alkaline conditions, while molybdenum passes through the column. This study was focused on determining whether radiolysis of an ABEC column used multiple times in a 20-Ci (Mo-99) generator could affect the recovery of technetium due to a radiolytic degradation of PEG. Irradiations were performed using a Van de Graaff generator.
- Research Organization:
- Argonne National Laboratory (ANL), Argonne, IL (United States)
- Sponsoring Organization:
- USDOE National Nuclear Security Administration (NNSA), Office of Defense Nuclear Nonproliferation
- Contributing Organization:
- NorthStar Medical Technologies, LLC
- DOE Contract Number:
- AC02-06CH11357
- OSTI ID:
- 1132239
- Report Number(s):
- ANL/CSE--13/18
- Country of Publication:
- United States
- Language:
- ENGLISH
Similar Records
New technologies for metal ion separations: aqueous biphasic extraction chromatography (ABEC). Part 1. Uptake of pertechnetate
Development Of ABEC Column For Separation Of Tc-99 From Northstar Dissolved Target Solution
Partitioning behavior of iodide with a aqueous biphasic extraction chromatographic (ABEC) resins
Journal Article
·
Thu Aug 01 00:00:00 EDT 1996
· Solvent Extraction and Ion Exchange
·
OSTI ID:374493
Development Of ABEC Column For Separation Of Tc-99 From Northstar Dissolved Target Solution
Technical Report
·
Wed Nov 30 23:00:00 EST 2016
·
OSTI ID:1349894
Partitioning behavior of iodide with a aqueous biphasic extraction chromatographic (ABEC) resins
Conference
·
Tue Oct 01 00:00:00 EDT 1996
·
OSTI ID:370528