Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings
This study examines the effective moisture penetration depth (EMPD) model, and its suitability for building simulations. The EMPD model is a compromise between the simple, inaccurate effective capacitance approach and the complex, yet accurate, finite-difference approach. Two formulations of the EMPD model were examined, including the model used in the EnergyPlus building simulation software. An error in the EMPD model we uncovered was fixed with the release of EnergyPlus version 7.2, and the EMPD model in earlier versions of EnergyPlus should not be used.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy Building Technologies Program
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1067948
- Report Number(s):
- NREL/TP-5500-57441
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of the Effective Moisture Penetration Depth Model for Estimating Moisture Buffering in Buildings
Effective moisture penetration depth model for residential buildings: Sensitivity analysis and guidance on model inputs
Moisture Modeling: Effective Moisture Penetration Depth Versus Effective Capacitance
Technical Report
·
Tue Jan 01 00:00:00 EST 2013
·
OSTI ID:1067948
Effective moisture penetration depth model for residential buildings: Sensitivity analysis and guidance on model inputs
Journal Article
·
Wed Jan 31 00:00:00 EST 2018
· Energy and Buildings
·
OSTI ID:1067948
Moisture Modeling: Effective Moisture Penetration Depth Versus Effective Capacitance
Conference
·
Thu Sep 01 00:00:00 EDT 2016
·
OSTI ID:1067948