IBS and Expected Luminosity Performance For RHIC Beams At Top Energy With 56 MHz SRF Cavity
- Brookhaven National Laboratory (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
The purpose of RF system in RHIC is to capture injected bunches, accelerate them to the top energy, and store bunches at the top energy for many hours. The accelerating RF system operates at harmonic number h=360 of the particle revolution frequency f=78.196 kHz, which corresponds to 28.15MHz. The storage RF system accepts the shortened bunches at top energy and provides longitudinal focusing to keep these bunches short during the store time (collision mode). The storage system operates at harmonic number h=7x360=2520, which corresponds to an RF frequency of 197.05 MHz.
- Research Organization:
- Brookhaven National Laboratory (BNL), Upton, NY (United States). Relativistic Heavy Ion Collider (RHIC)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 1061922
- Report Number(s):
- BNL--99481-2013-IR; BNL-81722-2008-IR; C-A/AP/#332; KB0202011
- Country of Publication:
- United States
- Language:
- English
Similar Records
IBS and expected luminosity performance for RHIC beams at top energy with 56 MHz SRF cavity
Design of the 28.15 MHz cavity for RHIC
Rf systems for RHIC
Technical Report
·
Wed Oct 01 00:00:00 EDT 2008
·
OSTI ID:944958
Design of the 28.15 MHz cavity for RHIC
Technical Report
·
Sun Oct 01 00:00:00 EDT 1995
·
OSTI ID:1118904
Rf systems for RHIC
Conference
·
Mon May 01 00:00:00 EDT 1995
·
OSTI ID:64336