skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A human factors approach towards the design of a new glovebox glove for Los Alamos National Laboratory

Technical Report ·
DOI:https://doi.org/10.2172/1048349· OSTI ID:1048349
 [1]
  1. Los Alamos National Laboratory

Present day glovebox gloves at Los Alamos National Laboratory (LANL) are underdeveloped and ergonomically inaccurate. This problem results in numerous sprain and strain injuries every year for employees who perform glovebox work. In addition to injuries, using the current glovebox glove design also contributes to breaches and contamination. The current glove used today at LANL has several problems: (1) The length of the fingers is incorrect, (2) the web spacing between the fingers is nonexistent, (3) the angles between each digit on the finger are incorrect, (4) the thumb is placed inaccurately, and (5) the length of the hand is incorrect. These problems present a need to correct the current glove design to decrease the risk of injuries, breaches, and contamination. Anthropometrics were researched to help find the best range of hand measurements to fix the current glove design. Anthropometrics is the measure of the human physical variation. Anthropometrics for this study were gathered from the American National Survey (ANSUR) data that was conducted by the U.S Army in 1988. The current glovebox glove uses anthropometrics from the 95th to 105th percentile range which is too large so the new gloves are going to implement data from a smaller range of percentile groups. The 105th percentile range represents measurements that exceed the human population but are needed to fit certain circumstance such as wearing several under gloves within the glovebox gloves. Anthropometrics used in this study include: 105th percentile measurements for joint circumference which was unchanged because the room for under gloves plus ease of hand insertion and extraction is needed, 80th percentile measurements for crotch length to allow workers to reach the web spacing in the glove, 20th percentile measurements for finger length to allow workers to reach the end of the glove, standard 10.5cm hand breadth to allow more room to accommodate under gloves, 45 degrees abduction angle for the thumb for better positioning, 45 degrees extension angle for the thumb for better positioning, and various angles for the other fingers to allow a more relaxed and natural fit. 3D modeling was used to implement the anthropometric data listed above onto an existing scanned solid model of a human hand. SolidWorks 2010 3-D modeling package was utilized to manipulate the hand model to represent the anthropometric data researched. The anthropometrics and modifications were reviewed by the University of New Mexico Department of Orthopedics hand surgeons. After all modifications and reviews were completed the model was printed out using stereolithography. The printed out model of the hand was used as a mold to create a prototype glovebox glove. The new mold was taken to Piercan USA to produce a 20mil Polyurethane/Hypalon glovebox glove. The Minnesota Dexterity test and Purdue Pegboard test were used to measure the dexterity of the prototype glovebox glove against a current 15 mil Hypalon LANL glovebox glove. Using the data from the tests a student t test was used to determine if there was a significant difference between the current hypalon glove results and the new prototype glove results. With a 95% confidence level the prototype showed to have a significantly lower mean difference from the current hypalon glovebox glove with the Minnesota Dexterity test. With a 95% confidence level the prototype showed to have a significantly higher mean difference from the current hypalon glovebox glove with the Purdue Pegboard test. A p value method was also performed to confirm the results of the student t test. A survey was also given to glovebox workers to determine if they preferred the new design. The best reaction from glovebox workers was the new thumb position, 73.2% of the sample population agreed with the new thumb position. Developing a new glovebox glove will improve the ergonomics of the hand for work performed, decrease exposure time, decreasing risk of breaching, increasing productivity, reducing injuries, and improving work performance. In the future the new glovebox glove can also be implemented in other research fields such as: pharmaceutical research and development, semiconducting industry, biohazard industry, and other laboratories conducting nuclear research and development.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
Sponsoring Organization:
DOE/LANL
DOE Contract Number:
AC52-06NA25396
OSTI ID:
1048349
Report Number(s):
LA-UR-12-23847; TRN: US201217%%24
Country of Publication:
United States
Language:
English