D-Zero Collider Detector Cryopump Design and Operation
The vacuum pumping of the CC Cryostat was anticipated to be dominated by a water vapor load. The Engineering Note 270, extrapolating from earlier experience, predicts the removal of water vapor will be the dominant pumping load and take ca. 45 days to remove at the pumping speed planned. Part of the planned pumping capability was a homemade, liquid nitrogen temperature, water vapor cryopump. This note describes the design, fabrication and performance experiences of the Cryopump described in the D0 assembly drawing 3740.514-ME-294693.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL
- Sponsoring Organization:
- DOE Office of Science
- DOE Contract Number:
- AC02-07CH11359
- OSTI ID:
- 1031807
- Report Number(s):
- FERMILAB-D0-EN-291
- Country of Publication:
- United States
- Language:
- English