Cryostat "UV" Relief Valve Selection and Process Flow

Technical Report ·
DOI:https://doi.org/10.2172/1030719· OSTI ID:1030719
This report describes the selection of the relief valves for the D-Zero cryostats. The selection was based on the flow requirements calculated in D-Zero engineering note 3740.214,224-EN-6 under fire conditions (1200 F, no vacuum) for the central cryostat; 264 SCFM. This value was calculated from section 5.3.5 of 'Pressure Relief Device Standards; S 1.3-Compressed Gas Storage Containers', published by the Compressed Gas Association, Inc. The flow calculated above is far greater than the required fire condition flow capacity of 264 SCFM. The improbable 70 F flow temperature value of 738 SCFM is still much greater than the required fire capacity. The flow capacity of the paralleled supplemental rupture disc is 2640 SCFM, independently greater than the fire condition flow requirement.
Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL
Sponsoring Organization:
DOE Office of Science
DOE Contract Number:
AC02-07CH11359
OSTI ID:
1030719
Report Number(s):
FERMILAB-D0-EN-100
Country of Publication:
United States
Language:
English

Similar Records

Argon Dewar Required Relief Flow Capacity
Technical Report · Mon Sep 28 00:00:00 EDT 1987 · OSTI ID:1030708

Helium pressures in RHIC vacuum cryostats and relief valve requirements from magnet cooling line failure
Conference · Mon Mar 28 00:00:00 EDT 2011 · OSTI ID:1018305

D-Zero Central Calorimeter Pressure Vessel and Vacuum Vessel Safety Notes
Technical Report · Thu Oct 25 00:00:00 EDT 1990 · OSTI ID:1031832