Helium pressures in RHIC vacuum cryostats and relief valve requirements from magnet cooling line failure
Conference
·
OSTI ID:1018305
A catastrophic failure of the RHIC magnet cooling lines, similar to the LHC superconducting bus failure incident, would pressurize the insulating vacuum in the magnet and transfer line cryostats. Insufficient relief valves on the cryostats could cause a structural failure. A SINDA/FLUINT{reg_sign} model, which simulated the 4.5K/4 atm helium flowing through the magnet cooling system distribution lines, then through a line break into the vacuum cryostat and discharging via the reliefs into the RHIC tunnel, had been developed to calculate the helium pressure inside the cryostat. Arc flash energy deposition and heat load from the ambient temperature cryostat surfaces were included in the simulations. Three typical areas: the sextant arc, the Triplet/DX/D0 magnets, and the injection area, had been analyzed. Existing relief valve sizes were reviewed to make sure that the maximum stresses, caused by the calculated maximum pressures inside the cryostats, did not exceed the allowable stresses, based on the ASME Code B31.3 and ANSYS results. The conclusions are as follows: (1) The S/F simulation results show that the highest internal pressure in the cryostats, due to the magnet line failure, is {approx}37 psig (255115 Pa); (2) Based on the simulation, the temperature on the cryostat chamber, INJ Q8-Q9, could drop to 228 K, which is lower than the material minimum design temperature allowed by the Code; (3) Based on the ASME Code and ANSYS results, the reliefs on all the cryostats inside the RHIC tunnel are adequate to protect the vacuum chambers when the magnet cooling lines fail; and (4) In addition to the pressure loading, the thermal deformations, due to the temperature decrease on the cryostat chambers, could also cause a high stress on the chamber, if not properly supported.
- Research Organization:
- Brookhaven National Laboratory (BNL) Relativistic Heavy Ion Collider
- Sponsoring Organization:
- DOE - OFFICE OF SCIENCE
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 1018305
- Report Number(s):
- BNL--94073-2011-CP; KB0202011
- Country of Publication:
- United States
- Language:
- English
Similar Records
Helium release rates and ODH calculations from RHIC magnet cooling line failure
High Pressure Source/Cryostat Relief Solutions
Cryostat design and analysis of the superconducting magnets for Jefferson Lab's 11-GEV/C super high momentum spectrometer
Conference
·
Mon Mar 28 00:00:00 EDT 2011
·
OSTI ID:1012265
High Pressure Source/Cryostat Relief Solutions
Technical Report
·
Thu Aug 13 00:00:00 EDT 1987
·
OSTI ID:1030705
Cryostat design and analysis of the superconducting magnets for Jefferson Lab's 11-GEV/C super high momentum spectrometer
Conference
·
Thu Apr 01 00:00:00 EDT 2010
·
OSTI ID:1010433