This report addresses solutions to the potential problem of cryostat over pressurization by the nominal 65 psi MWAP LAr source dewar. Uncontrolled (by reason of failure) filling of a 15 psi MW AP cryostat by the LAr fill line could cause over pressurization by overwhelming the provided cryostat relief system. Three levels of protection against over pressurization by the source dewar are mentioned in this report; the reduced (operational) relief pressure, the source pressure regulator, and the LAr dewar cooling loop. Only the first of these is recognized by the ASME code as sufficient protection, the others provide operational convenience and avoid the loss of detector fluid. Flow limiting device solutions are not considered because of the conflicting requirement to empty and fill the cryostats rapidly (within one eight hour shift), e.g. the movement of the cryostat from the assembly hall to the collision hall, or the inverse operation.
Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL
Sponsoring Organization:
DOE Office of Science
DOE Contract Number:
AC02-07CH11359
OSTI ID:
1030705
Report Number(s):
FERMILAB-D0-EN-115
Country of Publication:
United States
Language:
English

Similar Records

Cryostat Filling Limitations for Proposed Ar Dewar Pressure Increase
Technical Report · Tue Jul 23 00:00:00 EDT 1991 · OSTI ID:1031759

Technical Appendix to Cryogenic Pressure Vessels
Technical Report · Wed Feb 21 23:00:00 EST 1990 · OSTI ID:1031850

Argon Dewar Relief Set Pressure Modifications
Technical Report · Mon Mar 18 23:00:00 EST 1991 · OSTI ID:1031772