Design considerations for a 60 meter permanent magnet undulator for the SLAC Linac Coherent Light Source (LCLS)
Conference
·
OSTI ID:10186237
- Stanford Linear Accelerator Center, Menlo Park, CA (United States)
- California Univ., Los Angeles, CA (United States). Dept. of Physics
In this paper we describe design, fabrication, and measurement aspects of a pure permanent magnet (PM) insertion device designed to operate as an FEL at a 1st harmonic energy of 300 eV and an electron energy of 7 GeV in the Self-Amplified Spontaneous Emission (SASE) regime.
- Research Organization:
- Stanford Linear Accelerator Center, Menlo Park, CA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC03-76SF00515
- OSTI ID:
- 10186237
- Report Number(s):
- SLAC-PUB-6106; SLAC/SSRL-0020; CONF-930511-420; ON: DE93040955; TRN: 93:021829
- Resource Relation:
- Conference: PAC `93: international particle accelerator conference,Washington, DC (United States),17-20 May 1993; Other Information: PBD: Apr 1993
- Country of Publication:
- United States
- Language:
- English
Similar Records
Research and development toward a 4.5-1.5{angstrom} linac coherent light source (LCLS) at SLAC
Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)
Design Considerations for a 60-Meter Pure Permanent Magnet Undulator for the SLAC Linac Coherent Light Source (LCLS)
Conference
·
Sun Dec 31 00:00:00 EST 1995
·
OSTI ID:10186237
Infrared (IR) vs x-ray power generation in the SLAC Linac Coherent Light Source (LCLS)
Conference
·
Sat May 01 00:00:00 EDT 1993
·
OSTI ID:10186237
Design Considerations for a 60-Meter Pure Permanent Magnet Undulator for the SLAC Linac Coherent Light Source (LCLS)
Program Document
·
Wed Jun 13 00:00:00 EDT 2018
·
OSTI ID:10186237