Design considerations for a 60 meter permanent magnet undulator for the SLAC Linac Coherent Light Source (LCLS)
Conference
·
OSTI ID:10186237
- Stanford Linear Accelerator Center, Menlo Park, CA (United States)
- California Univ., Los Angeles, CA (United States). Dept. of Physics
In this paper we describe design, fabrication, and measurement aspects of a pure permanent magnet (PM) insertion device designed to operate as an FEL at a 1st harmonic energy of 300 eV and an electron energy of 7 GeV in the Self-Amplified Spontaneous Emission (SASE) regime.
- Research Organization:
- Stanford Linear Accelerator Center, Menlo Park, CA (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC03-76SF00515
- OSTI ID:
- 10186237
- Report Number(s):
- SLAC-PUB--6106; SLAC/SSRL--0020; CONF-930511--420; ON: DE93040955