skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Design considerations for a 60 meter permanent magnet undulator for the SLAC Linac Coherent Light Source (LCLS)

Abstract

In this paper we describe design, fabrication, and measurement aspects of a pure permanent magnet (PM) insertion device designed to operate as an FEL at a 1st harmonic energy of 300 eV and an electron energy of 7 GeV in the Self-Amplified Spontaneous Emission (SASE) regime.

Authors:
; ; ; ; ;  [1];  [2]
  1. Stanford Linear Accelerator Center, Menlo Park, CA (United States)
  2. California Univ., Los Angeles, CA (United States). Dept. of Physics
Publication Date:
Research Org.:
Stanford Linear Accelerator Center, Menlo Park, CA (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
10186237
Report Number(s):
SLAC-PUB-6106; SLAC/SSRL-0020; CONF-930511-420
ON: DE93040955; TRN: 93:021829
DOE Contract Number:  
AC03-76SF00515
Resource Type:
Conference
Resource Relation:
Conference: PAC `93: international particle accelerator conference,Washington, DC (United States),17-20 May 1993; Other Information: PBD: Apr 1993
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; WIGGLER MAGNETS; DESIGN; SYNCHROTRON RADIATION SOURCES; LIGHT SOURCES; FREE ELECTRON LASERS; TOLERANCE; 430303; EXPERIMENTAL FACILITIES AND EQUIPMENT

Citation Formats

Tatchyn, R, Boyce, R, Halbach, K, Nuhn, H D, Seeman, J, Winick, H, and Pellegrini, C. Design considerations for a 60 meter permanent magnet undulator for the SLAC Linac Coherent Light Source (LCLS). United States: N. p., 1993. Web.
Tatchyn, R, Boyce, R, Halbach, K, Nuhn, H D, Seeman, J, Winick, H, & Pellegrini, C. Design considerations for a 60 meter permanent magnet undulator for the SLAC Linac Coherent Light Source (LCLS). United States.
Tatchyn, R, Boyce, R, Halbach, K, Nuhn, H D, Seeman, J, Winick, H, and Pellegrini, C. 1993. "Design considerations for a 60 meter permanent magnet undulator for the SLAC Linac Coherent Light Source (LCLS)". United States. https://www.osti.gov/servlets/purl/10186237.
@article{osti_10186237,
title = {Design considerations for a 60 meter permanent magnet undulator for the SLAC Linac Coherent Light Source (LCLS)},
author = {Tatchyn, R and Boyce, R and Halbach, K and Nuhn, H D and Seeman, J and Winick, H and Pellegrini, C},
abstractNote = {In this paper we describe design, fabrication, and measurement aspects of a pure permanent magnet (PM) insertion device designed to operate as an FEL at a 1st harmonic energy of 300 eV and an electron energy of 7 GeV in the Self-Amplified Spontaneous Emission (SASE) regime.},
doi = {},
url = {https://www.osti.gov/biblio/10186237}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Apr 01 00:00:00 EST 1993},
month = {Thu Apr 01 00:00:00 EST 1993}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: