A study of start-up characteristics of a potassium heat pipe from the frozen state
The start-up characteristics of a potassium heat pipe were studied both analytically and experimentally. Using the radiation heat transfer mode the heat pipe was tested in a vacuum chamber. The transition temperature calculated for potassium was then compared with the experimental results of the heat pipe with various heat inputs. These results show that the heat pipe was inactive until it reached the transition temperature. In addition, during the start-up period, the evaporator experienced dry-out with a heat input smaller than the capillary limit calculated at the steady state. However, when the working fluid at the condenser was completely melted, the evaporator was rewetted without external aid. The start-up period was significantly reduced with a large heat input.
- Research Organization:
- NASA Lewis Research Center, Cleveland, OH (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States); National Aeronautics and Space Administration, Washington, DC (United States)
- DOE Contract Number:
- AI03-86SF16310
- OSTI ID:
- 10181007
- Report Number(s):
- NASA-CR-189173; CONF-920804-29; ON: DE94051195; TRN: 94:008268
- Resource Relation:
- Other Information: PBD: Apr 1992
- Country of Publication:
- United States
- Language:
- English
Similar Records
Mathematical modeling and analysis of heat pipe start-up from the frozen state
Mathematical modeling and analysis of heat pipe start-up from the frozen state. Final report
Related Subjects
42 ENGINEERING
HEAT PIPES
EXPERIMENTAL DATA
THERMAL ANALYSIS
CAPILLARY FLOW
MATHEMATICAL MODELS
SPACE POWER REACTORS
NESDPS Office of Nuclear Energy Space and Defense Power Systems
210600
420200
POWER REACTORS, MOBILE, PROPULSION, PACKAGE, AND TRANSPORTABLE
FACILITIES, EQUIPMENT, AND TECHNIQUES