Cool-down and frozen start-up behavior of a grooved water heat pipe
A grooved water heat pipe was tested to study its characteristics during the cool-down and start-up periods. The water heat pipe was cooled down from the ambient temperature to below the freezing temperature of water. During the cool-down, isothermal conditions were maintained at the evaporator and adiabatic sections until the working fluid was frozen. When water was frozen along the entire heat pipe, the heat pipe was rendered inactive. The start-up of the heat pipe from this state was investigated under several different operating conditions. The results show the existence of large temperature gradients between the evaporator and the condenser, and the moving of the melting front of the working fluid along the heat pipe. Successful start-up was achieved for some test cases using partial gravity assist. The start-up behavior depended largely on the operating conditions.
- Research Organization:
- NASA Lewis Research Center, Cleveland, OH (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States); National Aeronautics and Space Administration, Washington, DC (United States)
- DOE Contract Number:
- AI03-86SF16310
- OSTI ID:
- 10181001
- Report Number(s):
- NASA-CR-187053; CONF-910318-17; ON: DE94051193; TRN: 94:008266
- Resource Relation:
- Other Information: PBD: Dec 1990
- Country of Publication:
- United States
- Language:
- English
Similar Records
Mathematical modeling and analysis of heat pipe start-up from the frozen state
Transient analysis of the start-up of a water heat pipe from a frozen state
Related Subjects
42 ENGINEERING
HEAT PIPES
MATHEMATICAL MODELS
TESTING
THAWING
EXPERIMENTAL DATA
SPACE POWER REACTORS
NESDPS Office of Nuclear Energy Space and Defense Power Systems
210600
420200
POWER REACTORS, MOBILE, PROPULSION, PACKAGE, AND TRANSPORTABLE
FACILITIES, EQUIPMENT, AND TECHNIQUES