Performance testing of extremity dosimeters -- pilot test
Technical Report
·
OSTI ID:10173079
- Pacific Northwest Lab., Richland, WA (US)
A working group of the Health Physics Society Standards Committee (HPSSC) has issued a draft standard for extremity dosimeters. To determine the appropriateness of the proposed standard, Pacific Northwest Laboratory (PNL) has conducted three separate evaluations of the performance by processors of extremity dosimeters. The dosimeters were tested in each of the irradiation categories specified in the draft standard: high-energy photons (general and accident dosimetry); low-energy photons (general and accident dosimetry); beta particles, neutrons (first and second evaluations only, neutron category was dropped for the last evaluation); and a mixture category. In the first evaluation only about 60% of the processors met the draft standard`s performance criteria for accuracy and precision. The second evaluation showed an overall improvement of 15% to 18%, but most processors were still unable to meet the performance criteria consistently in all irradiation categories. After these evaluations, PNL suggested several changes to the draft standard, including redefining some of the test categories and making the tolerance levels of the criteria more consistent with those in the standard for whole-body dosimetry. This report summarizes the third evaluation, which yielded an overall pass rate of 87%. Suggestions are given to render the draft standard generally more consistent with the criteria for whole-body dosimetry.
- Research Organization:
- Nuclear Regulatory Commission, Washington, DC (United States). Div. of Regulatory Applications; Pacific Northwest Lab., Richland, WA (United States)
- Sponsoring Organization:
- Nuclear Regulatory Commission, Washington, DC (United States)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 10173079
- Report Number(s):
- NUREG/CR--5989; PNL--8467; ON: TI93018177
- Country of Publication:
- United States
- Language:
- English
Similar Records
Performance testing of extremity dosimeters -- pilot test
Performance testing of extremity dosimeters
Performance testing of extremity dosimeters, Study 2
Technical Report
·
Thu Jul 01 00:00:00 EDT 1993
·
OSTI ID:6282716
Performance testing of extremity dosimeters
Technical Report
·
Mon Jun 01 00:00:00 EDT 1987
·
OSTI ID:6352251
Performance testing of extremity dosimeters, Study 2
Technical Report
·
Sat Mar 31 23:00:00 EST 1990
·
OSTI ID:7199063