Analysis of the ITER LFS Reflectometer Transmission Line System

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.3485086· OSTI ID:1016590
A critical issue in the design of the ITER Low Field Side (LFS) reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of ~42 m of corrugated waveguide and up to 10 miter bends. Important issues for the performance of the TL system are mode conversion and reflections. Minimizing mode conversion and reflections in the waveguide are critical to minimizing standing waves and phase errors in the reflectometer-measured phase. The performance of the corrugated waveguide and miter bends is analyzed and recommendations given.
Research Organization:
Oak Ridge National Laboratory (ORNL)
Sponsoring Organization:
SC USDOE - Office of Science (SC)
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1016590
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 81; ISSN 0034-6748
Country of Publication:
United States
Language:
English

Similar Records

Analysis of the ITER Low Field Side Reflectometer Transmission Line System
Journal Article · Thu Dec 31 23:00:00 EST 2009 · Review of Scientific Instruments · OSTI ID:1118795

ITER ECH Transmission Line System Design and Status
Conference · Fri Nov 01 00:00:00 EDT 2024 · OSTI ID:2480047

LOSS ESTIMATE FOR ITER ECH TRANSMISSION LINE INCLUDING MULTIMODE PROPAGATION
Journal Article · Thu Dec 31 23:00:00 EST 2009 · Fusion Science and Technology · OSTI ID:1081809

Related Subjects