LOSS ESTIMATE FOR ITER ECH TRANSMISSION LINE INCLUDING MULTIMODE PROPAGATION
Journal Article
·
· Fusion Science and Technology
OSTI ID:1081809
- Massachusetts Institute of Technology (MIT)
- ORNL
The ITER electron cyclotron heating (ECH) transmission lines (TLs) are 63.5-mm-diam corrugated waveguides that will each carry 1 MW of power at 170 GHz. The TL is defined here as the corrugated wave guide system connecting the gyrotron mirror optics unit (MO U) to the entrance of the ECH launcher and includes miter bends and other corrugated wave guide components. The losses on the ITER TL have been calculated for four possible cases corresponding to having HE(11) mode purity at the input of the TL of 100, 97, 90, and 80%. The losses due to coupling, ohmic, and mode conversion loss are evaluated in detail using a numerical code and analytical approaches. Estimates of the calorimetric loss on the line show that the output power is reduced by about 5, +/- 1% because of ohmic loss in each of the four cases. Estimates of the mode conversion loss show that the fraction of output power in the HE(11) mode is similar to 3% smaller than the fraction of input power in the HE(11) mode. High output mode purity therefore can be achieved only with significantly higher input mode purity. Combining both ohmic and mode conversion loss, the efficiency of the TL from the gyrotron MOU to the ECH launcher can be roughly estimated in theory as 92% times the fraction of input power in the HE(11) mode.
- Research Organization:
- Oak Ridge National Laboratory (ORNL)
- Sponsoring Organization:
- SC USDOE - Office of Science (SC)
- DOE Contract Number:
- AC05-00OR22725
- OSTI ID:
- 1081809
- Journal Information:
- Fusion Science and Technology, Journal Name: Fusion Science and Technology Journal Issue: 3 Vol. 57
- Country of Publication:
- United States
- Language:
- English
Similar Records
ITER ECH Transmission Line System Design and Status
Design of Matching Optics Unit (MOU) for coaxial ITER gyrotron
A quasi-optical resonant ring for high power millimeter-wave testing
Conference
·
Fri Nov 01 00:00:00 EDT 2024
·
OSTI ID:2480047
Design of Matching Optics Unit (MOU) for coaxial ITER gyrotron
Conference
·
Fri Jul 01 00:00:00 EDT 2011
·
OSTI ID:22078272
A quasi-optical resonant ring for high power millimeter-wave testing
Conference
·
Fri Aug 01 00:00:00 EDT 1997
·
OSTI ID:510436