Design of laser-Compton spot size monitor

Conference ·
OSTI ID:10162323
;  [1]; ; ; ;  [2]; ; ;  [3]
  1. National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan)
  2. Kawasaki Heavy Industries Ltd., Kobe (Japan)
  3. Stanford Linear Accelerator Center, Menlo Park, CA (United States)
A new diagnostic method for measuring transverse size of electron beam by nondestructive interaction of Compton scattering of laser beam has been proposed. A first model of this spot size monitor is under construction for the FFTB -- SLAC experiment, in order to measure the electron beam size of 60 nanometer vertical by 1 micrometer horizontal, using Nd: YAG-laser of 1.064 {mu}m wavelength. In this paper, the design of the system, and essential and practical engineering problems are discussed.