Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A review of Hanford power level limits

Technical Report ·
DOI:https://doi.org/10.2172/10147633· OSTI ID:10147633
As for any nuclear reactor, the operation of the Hanford reactors is governed by many technical and administrative considerations. With the completion of current project action, later this year, certain of the technical limitations on reactor power level will be relieved, notably at the K Reactors, At that time, the technical and engineering limitations will be more liberal at some reactors than required for operation at the administrative power level limits, imposed by the Atomic Energy Commission, that are currently in force. The following report discusses the various technical factors governing reactor power levels and compares these with the currently imposed administrative power level limits.
Research Organization:
General Electric Co., Richland, WA (United States). Hanford Atomic Products Operation
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-76RL01830
OSTI ID:
10147633
Report Number(s):
HW--74122; ON: DE94010964
Country of Publication:
United States
Language:
English

Similar Records

Reactor power level limits
Technical Report · Mon Dec 02 23:00:00 EST 1963 · OSTI ID:10189768

Future power levels of Hanford Piles
Technical Report · Tue May 31 00:00:00 EDT 1955 · OSTI ID:10104673

POWER LEVEL AND ENRICHMENT LIMITATIONS OF THE HANFORD TEST PILE